What Limits a Reference Rate: The State Definition, Not the Estimator

Enhanced-sampling methods are validated against reference rates from long unbiased simulations, and the reference is treated as the answer. We show that the reference carries an accuracy floor set by an analysis choice that is almost never reported. Using 39.2 μs of alanine dipeptide in explicit water, in 16 replicas totaling 196 million analyzed frames, we apply two accepted rate estimators to two conventional definitions of the same conformational transition in a full two-by-two design. Given matched states, the Hill relation and core-set milestoning agree to between 0.08 and 0.56%. Given matched estimators, two ordinary definitions of the same transition, angular cores and a distance-difference threshold, disagree by 6.4 to 7.0%. The offset does not diminish as sampling increases from 15.0 to 39.2 μs. It is negligible on a transition 721 to 769 times slower depending on which definition sets the comparison, where the two definitions select event sets differing by a single count, and a Markov state model cannot arbitrate because no lag is simultaneously long enough for Markovianity and short enough to leave a 143 ps mean first passage time undistorted. Reference rates should be published with their state definitions.

Authors

Institutions

Publication Details

Journal
The Journal of Physical Chemistry B
Published
2026-11-18
DOI
https://doi.org/10.1021/acs.jpcb.6c05431
Primary Topic
Protein Structure and Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

What Limits a Reference Rate: The State Definition, Not the Estimator

Khaled M. Elokely, Laxman Mahadev Alakonda, Manal A. Nael
1 links
The Journal of Physical Chemistry B
Protein Structure and Dynamics
article

What Limits a Reference Rate: The State Definition, Not the Estimator

Khaled M. Elokely, Laxman Mahadev Alakonda, Manal A. Nael
article en

Abstract

Enhanced-sampling methods are validated against reference rates from long unbiased simulations, and the reference is treated as the answer. We show that the reference carries an accuracy floor set by an analysis choice that is almost never reported. Using 39.2 μs of alanine dipeptide in explicit water, in 16 replicas totaling 196 million analyzed frames, we apply two accepted rate estimators to two conventional definitions of the same conformational transition in a full two-by-two design. Given matched states, the Hill relation and core-set milestoning agree to between 0.08 and 0.56%. Given matched estimators, two ordinary definitions of the same transition, angular cores and a distance-difference threshold, disagree by 6.4 to 7.0%. The offset does not diminish as sampling increases from 15.0 to 39.2 μs. It is negligible on a transition 721 to 769 times slower depending on which definition sets the comparison, where the two definitions select event sets differing by a single count, and a Markov state model cannot arbitrate because no lag is simultaneously long enough for Markovianity and short enough to leave a 143 ps mean first passage time undistorted. Reference rates should be published with their state definitions.

The Journal of Physical Chemistry B
University of Wyoming (US)
National Institute of General Medical Sciences
Protein Structure and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon