Non-Invasive Glucose Monitoring Using mμSORS: A Population-Based Validation Study Across Diverse Patient Variability

Background: Frequent glucose monitoring is essential for diabetes management, yet non-invasive approaches have been limited by poor generalizability across patients. This study aimed to evaluate whether a depth-resolved Raman spectroscopy approach can provide consistent glucose prediction accuracy across physiological variability. Methods: We enrolled 200 patients with type 2 diabetes and acquired depth-resolved Raman spectra using a multiple μ-spatially offset Raman spectroscopy (mμSORS) system. An overall partial least squares (PLS) model was developed using 4768 paired venous plasma glucose and concatenated spectra at 100 μm (offset 2) and 150 μm (offset 3), and validated by subject-wise tenfold cross-validation. Model robustness was assessed through stratified analyses across physical characteristics, skin parameters, and serum biomarkers, with size-matched comparisons to control for sample size effects. Prediction accuracy was evaluated using mean absolute relative difference (MARD), root mean square error (RMSE), and consensus error grid (CEG). Results: The dataset covered a wide glucose range (3.8-31.6 mmol/L; 68.4-568.8 mg/dL) and substantial physiological heterogeneity. The overall PLS model achieved a MARD of 14.5% (CEG A + B: 99.4%), with no significant differences across stratified subgroups ( P > .05). Stratified subgroup models performed significantly worse than the overall model ( P < .05), yet after controlling for sample size, their performance was comparable with that of the overall model. Conclusion: A single, overall model for mμSORS-based glucose monitoring achieves high accuracy across diverse patient subgroups, demonstrating its strong robustness. These findings support the clinical potential of depth-resolved Raman spectroscopy for non-invasive glucose monitoring. Trial Registration: ClinicalTrials.gov NCT05921344; https://clinicaltrials.gov/study/NCT05921344 .

Authors

Institutions

Publication Details

Journal
Journal of Diabetes Science and Technology
Published
2026-08-18
DOI
https://doi.org/10.1177/19322968261464571
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Glucose Monitoring Using mμSORS: A Population-Based Validation Study Across Diverse Patient Variability

You Wu, 张先彪, Xiaoru Feng, Bei Tao et al.
Journal of Diabetes Science and Technology
Spectroscopy Techniques in Biomedical and Chemical Research
article

Non-Invasive Glucose Monitoring Using mμSORS: A Population-Based Validation Study Across Diverse Patient Variability

You Wu, 张先彪, Xiaoru Feng, Bei Tao, Lili Zhang, Minghui Chen, Yuran Xu, Yifei Zhang, Weiqing Wang, Lin Zhou, Chang Chen, Jia Shi, Long Wang, Yufei Chen, Yue Shen
article en

Abstract

Background: Frequent glucose monitoring is essential for diabetes management, yet non-invasive approaches have been limited by poor generalizability across patients. This study aimed to evaluate whether a depth-resolved Raman spectroscopy approach can provide consistent glucose prediction accuracy across physiological variability. Methods: We enrolled 200 patients with type 2 diabetes and acquired depth-resolved Raman spectra using a multiple μ-spatially offset Raman spectroscopy (mμSORS) system. An overall partial least squares (PLS) model was developed using 4768 paired venous plasma glucose and concatenated spectra at 100 μm (offset 2) and 150 μm (offset 3), and validated by subject-wise tenfold cross-validation. Model robustness was assessed through stratified analyses across physical characteristics, skin parameters, and serum biomarkers, with size-matched comparisons to control for sample size effects. Prediction accuracy was evaluated using mean absolute relative difference (MARD), root mean square error (RMSE), and consensus error grid (CEG). Results: The dataset covered a wide glucose range (3.8-31.6 mmol/L; 68.4-568.8 mg/dL) and substantial physiological heterogeneity. The overall PLS model achieved a MARD of 14.5% (CEG A + B: 99.4%), with no significant differences across stratified subgroups ( P > .05). Stratified subgroup models performed significantly worse than the overall model ( P < .05), yet after controlling for sample size, their performance was comparable with that of the overall model. Conclusion: A single, overall model for mμSORS-based glucose monitoring achieves high accuracy across diverse patient subgroups, demonstrating its strong robustness. These findings support the clinical potential of depth-resolved Raman spectroscopy for non-invasive glucose monitoring. Trial Registration: ClinicalTrials.gov NCT05921344; https://clinicaltrials.gov/study/NCT05921344 .

Journal of Diabetes Science and Technology
Johns Hopkins University (US), University of Shanghai for Science and Technology (CN), Shanghai Jiao Tong University (CN), Ruijin Hospital (CN), State Key Laboratory of Transducer Technology (CN), Shanghai Institute of Microsystem and Information Technology (CN), Tsinghua University (CN)
No poverty
Openalex Percentile: Top 11%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.