Waste Heat Recovery of a Thermal Power Plant

Thermal power plants still provide the bulk of electricity that can be dispatched on the grid in India and the rest of the developing world, but a significant portion of the energy they use is dissipated as low-quality heat into the environment. Much of this rejected energy is lost from the plant with the boiler flue gas at temperatures appropriate to make use of them but not high enough for a conventional steam bottoming cycle. A representative 210 MW subcritical coal fired unit is considered to recover the low-grade heat of the flue gas in a subcritical Organic Rankine Cycle (ORC) along with a machine-learning framework. A first law and second law thermodynamic model was developed in Python, where the flue gas source was initially at a temperature of 160 °C and subsequently cooled to a lower limit set by an acid dew-point. Seven candidate working fluids were considered and R1233zd(E) and R245fa were found to be most promising on both the performance and environmental aspects. A parametric study quantified the effect of evaporator pressure, condensation temperature, superheat, inlet temperature and mass flow of flue-gas on the net power and thermal efficiency. Five regressors have been trained with a dataset of approximately 2050 feasible operating points, with the best accuracy (R² = 0.991, RMSE = 0.049 MW), given by a gradient-boosted-tree (XGBoost) surrogate model, showing close agreement with the underlying thermodynamics in terms of the ranking of features. The surrogate successfully identified an optimum value that recovers ~2.60 MW of net power, which is within 1% of the optimum recovered in the full model, a ~1.2 percentage-point improvement in plant efficiency and an estimated annual abatement of ~18,000 t CO₂ at only over two orders of magnitude less computing cost than direct optimisation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-08-18
DOI
https://doi.org/10.5281/zenodo.21988810
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waste Heat Recovery of a Thermal Power Plant

Raghvendra Kumar Khedle, Mangesh Nachankar
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Waste Heat Recovery of a Thermal Power Plant

Raghvendra Kumar Khedle, Mangesh Nachankar
article en

Abstract

Thermal power plants still provide the bulk of electricity that can be dispatched on the grid in India and the rest of the developing world, but a significant portion of the energy they use is dissipated as low-quality heat into the environment. Much of this rejected energy is lost from the plant with the boiler flue gas at temperatures appropriate to make use of them but not high enough for a conventional steam bottoming cycle. A representative 210 MW subcritical coal fired unit is considered to recover the low-grade heat of the flue gas in a subcritical Organic Rankine Cycle (ORC) along with a machine-learning framework. A first law and second law thermodynamic model was developed in Python, where the flue gas source was initially at a temperature of 160 °C and subsequently cooled to a lower limit set by an acid dew-point. Seven candidate working fluids were considered and R1233zd(E) and R245fa were found to be most promising on both the performance and environmental aspects. A parametric study quantified the effect of evaporator pressure, condensation temperature, superheat, inlet temperature and mass flow of flue-gas on the net power and thermal efficiency. Five regressors have been trained with a dataset of approximately 2050 feasible operating points, with the best accuracy (R² = 0.991, RMSE = 0.049 MW), given by a gradient-boosted-tree (XGBoost) surrogate model, showing close agreement with the underlying thermodynamics in terms of the ranking of features. The surrogate successfully identified an optimum value that recovers ~2.60 MW of net power, which is within 1% of the optimum recovered in the full model, a ~1.2 percentage-point improvement in plant efficiency and an estimated annual abatement of ~18,000 t CO₂ at only over two orders of magnitude less computing cost than direct optimisation.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines