Latin America's First Active and Intelligent Packaging for Organ Transportation

ABSTRACT This study aimed to present and validate the Autonomous and Intelligent Packaging for the Cold Chain in Health Systems (EMAIS‐SR) for organ transport through an experimental model using porcine organs. To do so, Landrace porcine hearts, livers, pancreases and kidneys were transported using either EMAIS‐SR or traditional ice‐filled coolers. Following transport, organs were assessed after 2 h through collected data that included temperature monitoring, macroscopic evaluation, histological analysis and microbiological testing. Prototypes at different technology readiness levels (TRL6 and TRL7) were evaluated. Regarding the findings, EMAIS‐SR maintained organ temperatures predominantly within the recommended 2°C–8°C range. In the adjusted analysis, the TRL7 prototype achieved significantly lower post‐transport temperatures than TRL6 (adjusted difference: 2.91°C; 95% CI, 1.32–4.50; p = 0.0006), indicating improved thermal performance after system refinements. Additionally, minor macroscopic changes were observed in some samples, but without histological correlation. Histological analysis showed better tissue preservation in EMAIS‐SR samples, particularly in nuclei morphology and cytoplasmic structure. Furthermore, microbiological results indicated equivalent or lower contamination in EMAIS‐SR compared to the control, especially in later tests. Overall, EMAIS‐SR demonstrated effective thermal control, preservation of tissue integrity and biological safety in a structured preclinical model using porcine organs. Consequently, these findings validate EMAIS‐SR as a robust and clinically promising alternative to conventional organ transport systems.

Authors

Institutions

Publication Details

Journal
Packaging Technology and Science
Published
2026-08-17
DOI
https://doi.org/10.1002/pts.70110
Primary Topic
Tissue Engineering and Regenerative Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Latin America's First Active and Intelligent Packaging for Organ Transportation

Sibele Maria Schuantes Paim, André Ibrahim David, Janine Schirmer, Bartira de Aguiar Roza et al.
Packaging Technology and Science
Tissue Engineering and Regenerative Medicine
article

Latin America's First Active and Intelligent Packaging for Organ Transportation

Sibele Maria Schuantes Paim, André Ibrahim David, Janine Schirmer, Bartira de Aguiar Roza, Murched Omar Taha, Manuel de Jesus Simões, Vanessa Ayres Carneiro Gonçalves, Ana Paula Reis Nolêtto, Eliana Cavalari Teraoka, Renata Fabiana Leite, Graciana Maria de Moraes, José Homero Soares, Luciana Chelotti Cardim Perillo, Adriana Aparecida Ferraz Carbonel, Victor Hugo Marín Cruz, Julia Karini da Silva Araujo, Karoline Sabrina de Carvalho Gomes, Ari Nelson Rodrigues Costa, Selma Ferrer, Leandro Moriyama Konatu
article en

Abstract

ABSTRACT This study aimed to present and validate the Autonomous and Intelligent Packaging for the Cold Chain in Health Systems (EMAIS‐SR) for organ transport through an experimental model using porcine organs. To do so, Landrace porcine hearts, livers, pancreases and kidneys were transported using either EMAIS‐SR or traditional ice‐filled coolers. Following transport, organs were assessed after 2 h through collected data that included temperature monitoring, macroscopic evaluation, histological analysis and microbiological testing. Prototypes at different technology readiness levels (TRL6 and TRL7) were evaluated. Regarding the findings, EMAIS‐SR maintained organ temperatures predominantly within the recommended 2°C–8°C range. In the adjusted analysis, the TRL7 prototype achieved significantly lower post‐transport temperatures than TRL6 (adjusted difference: 2.91°C; 95% CI, 1.32–4.50; p = 0.0006), indicating improved thermal performance after system refinements. Additionally, minor macroscopic changes were observed in some samples, but without histological correlation. Histological analysis showed better tissue preservation in EMAIS‐SR samples, particularly in nuclei morphology and cytoplasmic structure. Furthermore, microbiological results indicated equivalent or lower contamination in EMAIS‐SR compared to the control, especially in later tests. Overall, EMAIS‐SR demonstrated effective thermal control, preservation of tissue integrity and biological safety in a structured preclinical model using porcine organs. Consequently, these findings validate EMAIS‐SR as a robust and clinically promising alternative to conventional organ transport systems.

Packaging Technology and Science
Instituto Mauá de Tecnologia (BR), Instituto de Tecnologia de Alimentos (BR), Camelback (Brazil) (BR), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (BR), Universidade Federal de São Paulo (BR)
Openalex Percentile: Top 7%
Tissue Engineering and Regenerative Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.