Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia

Background:This retrospective study from a single center aimed to compare postoperative visual, structural, and ocular hemodynamic outcomes following implantation of a trifocal intraocular lens (IOL) in 67 patients and a bifocal IOL in 67 patients with combined cataract and myopia. Material/Methods:A total of 134 patients (268 eyes) with cataract and myopia treated between June 2022 and June 2024 were retrospectively analyzed and divided into a bifocal IOL group (n = 67; 134 eyes) and a trifocal IOL group (n = 67; 134 eyes).All patients underwent standardized phacoemulsification with capsular bag IOL implantation and were evaluated 6 months postoperatively.Outcomes included visual acuity, intraocular pressure, anterior chamber depth, axial length, lens thickness, mean blood flow density, pulsatility index, and resistance index.Generalized estimating equation models were used to account for inter-eye correlation. Results:Compared with the bifocal IOL group, the trifocal IOL group showed lower postoperative intraocular pressure (P = 0.003) and anterior chamber depth (P = 0.004) and improved oculus dexter visual acuity (P = 0.003).Lens thickness was lower postoperatively, whereas axial length remained stable between groups.Mean blood flow density increased (P = 0.020), whereas pulsatility index (P = 0.003) and resistance index (P = 0.002) decreased.Adverse events were less frequent in the trifocal IOL group (P = 0.029).However, the observed differences were modest, with uncertain clinical significance. Conclusions:Trifocal IOL implantation was associated with limited postoperative differences in visual and hemodynamic outcomes compared with bifocal IOL implantation.These findings require cautious interpretation and validation in larger prospective studies with longer follow-up.

Authors

Institutions

Publication Details

Journal
Medical Science Monitor
Published
2026-08-18
DOI
https://doi.org/10.12659/msm.953476
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia

Man Xu, Xing Gao, Qilin Wu, Yan Shao
Medical Science Monitor
Ophthalmology and Visual Impairment Studies
article

Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia

Man Xu, Xing Gao, Qilin Wu, Yan Shao
article en

Abstract

Background:This retrospective study from a single center aimed to compare postoperative visual, structural, and ocular hemodynamic outcomes following implantation of a trifocal intraocular lens (IOL) in 67 patients and a bifocal IOL in 67 patients with combined cataract and myopia. Material/Methods:A total of 134 patients (268 eyes) with cataract and myopia treated between June 2022 and June 2024 were retrospectively analyzed and divided into a bifocal IOL group (n = 67; 134 eyes) and a trifocal IOL group (n = 67; 134 eyes).All patients underwent standardized phacoemulsification with capsular bag IOL implantation and were evaluated 6 months postoperatively.Outcomes included visual acuity, intraocular pressure, anterior chamber depth, axial length, lens thickness, mean blood flow density, pulsatility index, and resistance index.Generalized estimating equation models were used to account for inter-eye correlation. Results:Compared with the bifocal IOL group, the trifocal IOL group showed lower postoperative intraocular pressure (P = 0.003) and anterior chamber depth (P = 0.004) and improved oculus dexter visual acuity (P = 0.003).Lens thickness was lower postoperatively, whereas axial length remained stable between groups.Mean blood flow density increased (P = 0.020), whereas pulsatility index (P = 0.003) and resistance index (P = 0.002) decreased.Adverse events were less frequent in the trifocal IOL group (P = 0.029).However, the observed differences were modest, with uncertain clinical significance. Conclusions:Trifocal IOL implantation was associated with limited postoperative differences in visual and hemodynamic outcomes compared with bifocal IOL implantation.These findings require cautious interpretation and validation in larger prospective studies with longer follow-up.

Medical Science MonitorVol. 32
Shangluo University (CN), Sichuan Provincial Hospital of Traditional Chinese Medicine (CN), Xi’an Children’s Hospital (CN), Shangluo Central Hospital (CN), Seventh People's Hospital of Dalian (CN)
Openalex Percentile: Top 9%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.