Electrochemical biosensors for saxitoxin detection: advances, limitations, and challenges for market transition

Abstract Saxitoxins, produced by freshwater cyanobacteria and marine dinoflagellates, block neuronal sodium channels and can cause paralysis or death. They contaminate drinking water, bioaccumulate in aquatic organisms, and pose serious health risks. Conventional detection methods, though reliable, are costly, time-consuming, and require specialized personnel, limiting rapid or on-site use. Biosensors have emerged as attractive alternatives, with electrochemical platforms standing out for their high sensitivity, low cost, miniaturization potential, and easy integration into portable devices. These advantages make them promising tools for in situ monitoring of saxitoxins and justify a dedicated review. This work critically analyzes electrochemical biosensors for STX detection, highlighting advances, limitations, and challenges toward commercialization. We discuss operating principles, recognition elements, analytical performance, and classify devices by electrochemical technique (potentiometric, impedimetric, voltammetric), providing a comparative perspective on their respective strengths and limitations. Despite remarkable sensitivity—often below regulatory limits—key obstacles remain: lack of fabrication standardization, poor long-term stability, limited validation with naturally contaminated samples, insufficient robustness for complex matrices, low reproducibility, and absence of regulatory approval pathways. In addition, challenges associated with fabrication scalability and interlaboratory reproducibility continue to hinder the transition from proof-of-concept devices to commercially viable technologies. Overcoming these barriers is crucial for translating laboratory prototypes into reliable, field-deployable devices for environmental monitoring and food safety applications. Future developments should focus on improving robustness, reproducibility, and analytical validation to accelerate the practical implementation of electrochemical STX biosensors.

Authors

Publication Details

Journal
Environmental Monitoring and Assessment
Published
2026-08-18
DOI
https://doi.org/10.1007/s10661-026-15797-x
Primary Topic
Marine Toxins and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical biosensors for saxitoxin detection: advances, limitations, and challenges for market transition

Thiago Teixeira da Silva, Nirton Cristi Silva Vieira, Isadora Bernardes Sequalini, Larissa Victoria do Carmo de Oliveira
Environmental Monitoring and Assessment
Marine Toxins and Detection Methods
article

Electrochemical biosensors for saxitoxin detection: advances, limitations, and challenges for market transition

Thiago Teixeira da Silva, Nirton Cristi Silva Vieira, Isadora Bernardes Sequalini, Larissa Victoria do Carmo de Oliveira
article en

Abstract

Abstract Saxitoxins, produced by freshwater cyanobacteria and marine dinoflagellates, block neuronal sodium channels and can cause paralysis or death. They contaminate drinking water, bioaccumulate in aquatic organisms, and pose serious health risks. Conventional detection methods, though reliable, are costly, time-consuming, and require specialized personnel, limiting rapid or on-site use. Biosensors have emerged as attractive alternatives, with electrochemical platforms standing out for their high sensitivity, low cost, miniaturization potential, and easy integration into portable devices. These advantages make them promising tools for in situ monitoring of saxitoxins and justify a dedicated review. This work critically analyzes electrochemical biosensors for STX detection, highlighting advances, limitations, and challenges toward commercialization. We discuss operating principles, recognition elements, analytical performance, and classify devices by electrochemical technique (potentiometric, impedimetric, voltammetric), providing a comparative perspective on their respective strengths and limitations. Despite remarkable sensitivity—often below regulatory limits—key obstacles remain: lack of fabrication standardization, poor long-term stability, limited validation with naturally contaminated samples, insufficient robustness for complex matrices, low reproducibility, and absence of regulatory approval pathways. In addition, challenges associated with fabrication scalability and interlaboratory reproducibility continue to hinder the transition from proof-of-concept devices to commercially viable technologies. Overcoming these barriers is crucial for translating laboratory prototypes into reliable, field-deployable devices for environmental monitoring and food safety applications. Future developments should focus on improving robustness, reproducibility, and analytical validation to accelerate the practical implementation of electrochemical STX biosensors.

Environmental Monitoring and AssessmentVol. 198(9)
Openalex Percentile: Top 16%
Marine Toxins and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.