Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study
BACKGROUND: The Evolut and the Navitor transcatheter heart valves (THVs) represent the most widely used self-expanding implanted valves. Despite a similar implant concept, they markedly differ in design and hemodynamic performance. In both THVs, conduction disturbances following transcatheter aortic valve replacement (TAVR) are reported higher than in balloon-expandable devices. Nevertheless, to date, no direct comparative studies have analyzed their real difference rates. AIM: Aim of the present study was to directly compare the self-expanding Evolut PRO+ and Navitor THVs, with specific focus on the incidence of new permanent pacemaker implantation (PPI) and post-procedural hemodynamic performance. METHODS: The CONNAVIPRO registry is an international, multicenter, retrospective study including 880 consecutive patients with severe aortic stenosis treated with Evolut PRO+ (n = 451) or Navitor (n = 429) between May 2022 and December 2024. The primary endpoint was new PPI within 30 days among pacemaker-naïve patients. Secondary endpoints included technical and device success, transprosthetic gradients, and paravalvular leak (PVL). Inverse probability weighting (IPW) was applied to adjust for baseline differences. RESULTS: Procedural success was high with both valves (97.6%), and early safety outcomes were comparable. At 30 days, the Navitor group showed a higher PPI rate than Evolut (23.2% vs. 17.6%), reaching statistical significance after IPW adjustment (OR 1.53, 95% CI 1.08-2.17; p = 0.018). Mean transprosthetic gradients were slightly higher with Navitor (8 vs. 7 mmHg; p = 0.002), whereas moderate or greater PVL was less frequent (2.8% vs. 7.7%; p < 0.001). Variables independently associated with PPI were hypertension, and pre-existing right bundle branch block. CONCLUSIONS: Both Evolut PRO+ and Navitor THVs provided excellent safety and hemodynamic outcomes. Navitor may be associated with a higher 30-day PPI rate, a lower incidence of moderate or greater PVL, and clinically non-significant higher gradients. These associations should be interpreted as hypothesis-generating and warrant confirmation in prospective studies.
Authors
- Federico De Marco (ORCID: https://orcid.org/0000-0003-3554-6938)
- Andrea Zuffi
- Jacopo Oreglia (ORCID: https://orcid.org/0000-0002-8406-7696)
- O. Oliva (ORCID: https://orcid.org/0000-0002-5538-5222)
- Valentina Ardizzone
- Andrea Munafò (ORCID: https://orcid.org/0000-0002-5108-0579)
- Vittorio Zuccarelli (ORCID: https://orcid.org/0000-0002-0040-3825)
- Enrico Poletti (ORCID: https://orcid.org/0000-0002-3605-505X)
- Mauro Massussi (ORCID: https://orcid.org/0000-0003-0895-440X)
- Marianna Adamo (ORCID: https://orcid.org/0000-0002-3855-1815)
- Antonella Millin (ORCID: https://orcid.org/0009-0008-7184-4872)
- Giuseppe Esposito
- Baydaroglu Nurcan (ORCID: https://orcid.org/0009-0000-2459-5051)
- Ahmad Hassan (ORCID: https://orcid.org/0009-0005-9189-4090)
- Didier Tchetché
Institutions
- Rigshospitalet (DK)
- Ospedale Maggiore (IT)
- Centro Cardiologico Monzino (IT)
- Azienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda (IT)
- MultiMedica (IT)
- Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (IT)
- Clinique Pasteur (FR)
- Laboratoire Saint Martin (FR)
- University of Brescia (IT)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-08-17
- DOI
- https://doi.org/10.1002/ccd.70827
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00