Optimisation and Validation of a Microscale FRAP Assay with Matrix-Matched (Interaction-Corrected) Blanking for Accurate Antioxidant Capacity Assessment of Honeys

This study optimised and validated a microplate Ferric-Reducing Antioxidant Power (FRAP) assay for honey that incorporates a honey-specific matrix-matched blank—a paired absorbance measurement lacking the chromogenic probe 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ)—to separate true ferric reduction from non-reductive Fe3+–matrix interactions that otherwise inflate apparent antioxidant capacity. A 30 min incubation at 37 °C in the dark was selected as the optimal compromise between reaction completeness and reagent/matrix stability, using 20 µL sample and 180 µL FRAP reagent per well (absorbance at 620 nm). The assay was validated according to International Council for Harmonisation (ICH) principles, showing linearity for FeSO4·7H2O from 200–1200 µM (R2 ≥ 0.9988), Limit of detection/limit of quantification (LOD/LOQ) of 0.28/0.94 mmol Fe2+ equivalents kg−1, recoveries of 101–103%, and precision ≤ 5% relative standard deviation (RSD). All tested individual sugars except maltodextrin and the artificial honey matrix produced FRAP responses below the LOQ. Flavonoids, however, showed pronounced, time-dependent, non-reductive Fe3+ interactions and were markedly overestimated under conventional water blanking, while phenolic acids were less affected. Applied to 47 Western Australian honeys, the validated assay yielded FRAP activities of 2.80–9.52 mmol Fe2+ kg−1; matrix-matched blanking gave consistently lower, more chemically specific values than conventional water blanking, with corrections ranging up to >30% depending on honey type. Matrix-matched blanking is therefore essential, not optional, for accurate FRAP measurement in honey, and the same principle should apply directly to other phenolic-rich foods like wine, tea, and fruit extracts—wherever iron–polyphenol interactions confound conventional antioxidant assays.

Authors

Institutions

Publication Details

Journal
Methods and Protocols
Published
2026-08-18
DOI
https://doi.org/10.3390/mps9040120
Primary Topic
Bee Products Chemical Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimisation and Validation of a Microscale FRAP Assay with Matrix-Matched (Interaction-Corrected) Blanking for Accurate Antioxidant Capacity Assessment of Honeys

Lee Yong Lim, Ivan Lozada Lawag, Cornelia Locher, Sharmin Sultana
Methods and Protocols
Bee Products Chemical Analysis
article

Optimisation and Validation of a Microscale FRAP Assay with Matrix-Matched (Interaction-Corrected) Blanking for Accurate Antioxidant Capacity Assessment of Honeys

Lee Yong Lim, Ivan Lozada Lawag, Cornelia Locher, Sharmin Sultana
article en

Abstract

This study optimised and validated a microplate Ferric-Reducing Antioxidant Power (FRAP) assay for honey that incorporates a honey-specific matrix-matched blank—a paired absorbance measurement lacking the chromogenic probe 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ)—to separate true ferric reduction from non-reductive Fe3+–matrix interactions that otherwise inflate apparent antioxidant capacity. A 30 min incubation at 37 °C in the dark was selected as the optimal compromise between reaction completeness and reagent/matrix stability, using 20 µL sample and 180 µL FRAP reagent per well (absorbance at 620 nm). The assay was validated according to International Council for Harmonisation (ICH) principles, showing linearity for FeSO4·7H2O from 200–1200 µM (R2 ≥ 0.9988), Limit of detection/limit of quantification (LOD/LOQ) of 0.28/0.94 mmol Fe2+ equivalents kg−1, recoveries of 101–103%, and precision ≤ 5% relative standard deviation (RSD). All tested individual sugars except maltodextrin and the artificial honey matrix produced FRAP responses below the LOQ. Flavonoids, however, showed pronounced, time-dependent, non-reductive Fe3+ interactions and were markedly overestimated under conventional water blanking, while phenolic acids were less affected. Applied to 47 Western Australian honeys, the validated assay yielded FRAP activities of 2.80–9.52 mmol Fe2+ kg−1; matrix-matched blanking gave consistently lower, more chemically specific values than conventional water blanking, with corrections ranging up to >30% depending on honey type. Matrix-matched blanking is therefore essential, not optional, for accurate FRAP measurement in honey, and the same principle should apply directly to other phenolic-rich foods like wine, tea, and fruit extracts—wherever iron–polyphenol interactions confound conventional antioxidant assays.

Methods and ProtocolsVol. 9(4)
The University of Western Australia (AU), University of the Philippines Manila (PH)
Openalex Percentile: Top 10%
Bee Products Chemical Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.