Clinical evaluation of a novel artificial intelligence-based image processing algorithm for two-dimensional angiography
BACKGROUND: To evaluate the clinical performance of a novel artificial intelligence (AI)-based image processing algorithm for two-dimensional angiographic imaging compared with its predecessor across multiple imaging modes, anatomic regions, and endovascular specialties. MATERIALS AND METHODS: This retrospective, comparative, randomized, paired, and blinded multicenter reader study included anonymized images acquired during clinically indicated endovascular interventions at 11 institutions in the United States and Europe. A total of 553 image series from 182 patients representing 51 procedure types across interventional radiology, neurointervention, cardiology, and pediatric cardiology were processed using both the AI-based and predecessor image processing algorithms. Thirteen board-certified physicians independently evaluated paired images using five-point Likert scales for overall image quality, contrast of clinically relevant details, noise reduction, and confidence in assessing device and vessel details. The primary endpoint was non-inferiority of overall image quality. Secondary endpoints evaluated superiority across image quality metrics using a predefined hierarchical testing strategy. RESULTS: The AI-based image processing algorithm demonstrated non-inferior overall image quality in 98.9% of all evaluations (95% confidence interval [CI], 98%-100%), meeting the primary endpoint across all imaging modes, anatomic regions, and predefined subgroups. Superiority of the AI-based algorithm was demonstrated for overall image quality, contrast of clinically relevant details, noise reduction, and confidence in assessing device and vessel details across fluoroscopy, roadmap, overlay reference, and native acquisition imaging. Overall image quality superiority was not demonstrated for digital subtraction angiography, likely reflecting the intrinsically higher signal-to-noise characteristics of these acquisitions. Inter-reader agreement analysis demonstrated identical ratings in 49.3% of evaluations, with 94.7% of paired ratings differing by no more than one Likert category. CONCLUSIONS: In this multicenter blinded reader study, AI-based image processing demonstrated non-inferior overall image quality compared with its predecessor across all evaluated imaging modes and patient subgroups, with superior performance for multiple image quality metrics in fluoroscopy, roadmap, overlay reference, and native acquisition imaging. These findings support the clinical utility of AI-based image processing for endovascular imaging and provide a foundation for future studies evaluating its impact on radiation dose and procedural outcomes.
Authors
- Thomas Kästner
- Perwaiz Meraj (ORCID: https://orcid.org/0000-0002-6350-4666)
- Hector E. Tamez
- Jon C. George (ORCID: https://orcid.org/0000-0003-1797-3194)
- David C. Madoff (ORCID: https://orcid.org/0000-0003-3461-437X)
- Stanislav Tashenov (ORCID: https://orcid.org/0000-0001-5929-6748)
- Jeremy D. Asnes (ORCID: https://orcid.org/0000-0002-8634-7675)
- Joseph A. Puma
- Brian P. Quinn
- Eric Alexander Secemsky (ORCID: https://orcid.org/0000-0003-3861-3163)
- Michael J. Angtuaco (ORCID: https://orcid.org/0000-0003-4057-3690)
- Eric J. Hohenwalter
- Daniel H. Sahlein (ORCID: https://orcid.org/0000-0002-6591-9427)
- Randolph M. Setser (ORCID: https://orcid.org/0009-0002-1947-9974)
- Nancy Obuchowski
- John D. Barr
- Donald F. Frei
- David L. Lacey
Institutions
- Parkland Memorial Hospital (US)
- Parkland Health & Hospital System (US)
- Boston Children's Hospital (US)
- Arkansas Children's Hospital (US)
- Northwell Health (US)
- Beth Israel Deaconess Medical Center (US)
- Cleveland Clinic (US)
- Medical College of Wisconsin (US)
- North Shore University Hospital (US)
- Piedmont Atlanta Hospital (US)
- UnityPoint Health (US)
- Yale University (US)
- Swedish Medical Center (US)
- Lankenau Heart Institute (US)
- Southwestern Medical Center (US)
- Siemens Healthcare (United States) (US)
- Siemens Healthineers (Germany) (DE)
- Deaconess Hospital (US)
- Goodman Campbell Brain and Spine (US)
- University of Arkansas for Medical Sciences (US)
- The University of Texas Southwestern Medical Center (US)
Publication Details
- Journal
- CVIR Endovascular
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1186/s42155-026-00785-6
- Primary Topic
- Radiation Dose and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Siemens Healthineers