Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah

In recent years, the demand for indoor radon and air quality monitors has increased while more affordable consumer-grade monitors have become available. The aim of our study was to assess the validity of the less expensive, non-calibrated, consumer-grade Lüft (SunRADON LLC, Melbourne, FL, USA) compared to the more expensive, annually and manufacturer calibrated, industrial-grade Model 1028 XP (SunRADON LLC, Melbourne, FL, USA). We collected data about 24 h moving averages of barometric pressure, carbon dioxide (CO2), radon, relative humidity, temperature, and volatile organic compounds (VOC) for approximately 29 weeks in 2024 in each of six rooms in a school in Utah. The mean difference in the co-located Lüfts’ and Model 1028 XPs’ 24 h moving average radon was −0.05 pCi/L of air (95% confidence interval: −0.24, 0.14, p = 0.50) and the concordance correlation coefficient (CCC) was 0.92. The Lüfts’ and Model 1028 XPs’ 24 h moving averages were similar for barometric pressure (CCC: 0.87), but the Lüfts’ 24 h moving averages were lower than the Model 1028 XPs’ for CO2, relative humidity, and VOC and higher for temperature. The Lüft provided valid measurements of 24 h moving averages for barometric pressure and radon, but not for CO2, relative humidity, temperature, and VOC.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-18
DOI
https://doi.org/10.3390/s26165230
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah

Philip Lundrigan, John D. Beard, Christopher Kitras, Maren M. Ball
Sensors
Air Quality Monitoring and Forecasting
article

Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah

Philip Lundrigan, John D. Beard, Christopher Kitras, Maren M. Ball
article en

Abstract

In recent years, the demand for indoor radon and air quality monitors has increased while more affordable consumer-grade monitors have become available. The aim of our study was to assess the validity of the less expensive, non-calibrated, consumer-grade Lüft (SunRADON LLC, Melbourne, FL, USA) compared to the more expensive, annually and manufacturer calibrated, industrial-grade Model 1028 XP (SunRADON LLC, Melbourne, FL, USA). We collected data about 24 h moving averages of barometric pressure, carbon dioxide (CO2), radon, relative humidity, temperature, and volatile organic compounds (VOC) for approximately 29 weeks in 2024 in each of six rooms in a school in Utah. The mean difference in the co-located Lüfts’ and Model 1028 XPs’ 24 h moving average radon was −0.05 pCi/L of air (95% confidence interval: −0.24, 0.14, p = 0.50) and the concordance correlation coefficient (CCC) was 0.92. The Lüfts’ and Model 1028 XPs’ 24 h moving averages were similar for barometric pressure (CCC: 0.87), but the Lüfts’ 24 h moving averages were lower than the Model 1028 XPs’ for CO2, relative humidity, and VOC and higher for temperature. The Lüft provided valid measurements of 24 h moving averages for barometric pressure and radon, but not for CO2, relative humidity, temperature, and VOC.

SensorsVol. 26(16)
Brigham Young University (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 16%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah — Philip Lundrigan, John D. Beard, et al. · Sensors (2026) | TGRS Research Map | TGRS