Comparative outcomes of balloon-expandable versus self-expanding transcatheter aortic valves: insights from a large-scale German registry

Abstract Background While transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (SAVR), the comparative outcomes of balloon-expandable (BE) and self-expanding (SE) valve technologies remain an area of ongoing investigation. Methods Using the German DESTATIS database, we analyzed 48,565 transfemoral TAVR procedures performed between 2021 and 2022. Outcomes were compared between BE ( n = 23,412) and SE ( n = 25,153) valves using a double/debiased machine learning estimator to account for potential confounding. Key endpoints included in-hospital mortality, major bleeding, stroke, acute kidney injury, mechanical ventilation > 48 h, postoperative delirium, permanent pacemaker implantation (PPI), length of hospital stay, and reimbursement. Results Descriptively, SE valves were associated with significantly lower in-hospital mortality (1.6% vs. 2.0%, p < 0.001) and major bleeding (1.4% vs. 2.1%, p < 0.001) but a higher risk of stroke (2.4% vs. 1.9%, p < 0.001). A trend towards higher risk of PPI was observed ( p = 0.078). After adjustment, patients with SE valves are at lower risk for in-hospital mortality (RR 0.85, p = 0.049) and major bleeding (RR 0.78, p = 0.006), but had a higher risk of stroke (RR 1.35, p < 0.001) and permanent pacemaker implantation (RR 1.09, p = 0.028). Subgroup analysis indicated that older and high-risk patients, particularly those aged ≥ 85 years, showed a stronger association with lower in-hospital mortality for SE valves, whereas younger patients exhibited a trend favouring BE valves. BE valves were also associated with a modestly higher reimbursement (€209 per case, p = 0.004). Conclusion In this large, real-world cohort, self-expanding valves were associated with lower in-hospital mortality and major bleeding but a higher risk of stroke and permanent pacemaker implantation compared with balloon-expandable valves. Because prosthesis choice in routine practice is highly individualized and driven by anatomical and procedural factors not captured in administrative data, these associations are hypothesis-generating and cannot support device-selection recommendations.

Authors

Institutions

Publication Details

Journal
BMC Cardiovascular Disorders
Published
2026-08-18
DOI
https://doi.org/10.1186/s12872-026-06462-9
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative outcomes of balloon-expandable versus self-expanding transcatheter aortic valves: insights from a large-scale German registry

Dennis Wolf, Martin Czerny, Ingo Hilgendorf, Dirk Westermann et al.
BMC Cardiovascular Disorders
Cardiac Valve Diseases and Treatments
article

Comparative outcomes of balloon-expandable versus self-expanding transcatheter aortic valves: insights from a large-scale German registry

Dennis Wolf, Martin Czerny, Ingo Hilgendorf, Dirk Westermann, Constantin von zur Mühlen, Jonathan Rilinger, Klaus Kaier, Derek Hazard, Christian Valina
article en

Abstract

Abstract Background While transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (SAVR), the comparative outcomes of balloon-expandable (BE) and self-expanding (SE) valve technologies remain an area of ongoing investigation. Methods Using the German DESTATIS database, we analyzed 48,565 transfemoral TAVR procedures performed between 2021 and 2022. Outcomes were compared between BE ( n = 23,412) and SE ( n = 25,153) valves using a double/debiased machine learning estimator to account for potential confounding. Key endpoints included in-hospital mortality, major bleeding, stroke, acute kidney injury, mechanical ventilation > 48 h, postoperative delirium, permanent pacemaker implantation (PPI), length of hospital stay, and reimbursement. Results Descriptively, SE valves were associated with significantly lower in-hospital mortality (1.6% vs. 2.0%, p < 0.001) and major bleeding (1.4% vs. 2.1%, p < 0.001) but a higher risk of stroke (2.4% vs. 1.9%, p < 0.001). A trend towards higher risk of PPI was observed ( p = 0.078). After adjustment, patients with SE valves are at lower risk for in-hospital mortality (RR 0.85, p = 0.049) and major bleeding (RR 0.78, p = 0.006), but had a higher risk of stroke (RR 1.35, p < 0.001) and permanent pacemaker implantation (RR 1.09, p = 0.028). Subgroup analysis indicated that older and high-risk patients, particularly those aged ≥ 85 years, showed a stronger association with lower in-hospital mortality for SE valves, whereas younger patients exhibited a trend favouring BE valves. BE valves were also associated with a modestly higher reimbursement (€209 per case, p = 0.004). Conclusion In this large, real-world cohort, self-expanding valves were associated with lower in-hospital mortality and major bleeding but a higher risk of stroke and permanent pacemaker implantation compared with balloon-expandable valves. Because prosthesis choice in routine practice is highly individualized and driven by anatomical and procedural factors not captured in administrative data, these associations are hypothesis-generating and cannot support device-selection recommendations.

BMC Cardiovascular DisordersVol. 26(1)
University of Freiburg (DE), University Medical Center Freiburg (DE), Universitäts-Herzzentrum Freiburg-Bad Krozingen (DE)
Good health and well-being
Openalex Percentile: Top 9%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.