Comparative Study of Cathodic Protection Effects on Corrosion and Biofouling of Bronze Alloys in Marine Environment and Laboratory Conditions

Cathodic protection (CP) is used in the marine industry to prevent corrosion of metal components in seawater but may also promote biofilm formation. When steel and copper alloy components are in contact, the latter is often subjected to higher applied CP voltages than otherwise required when a steel component is not present. In this study, the protection that CP offers in bronze alloys (RG-10 and CC492K) was assessed, both in controlled laboratory conditions and in real marine conditions in the Bay of Biscay (up to 3000 h), with various temperatures and methods: sacrificial anodes and impressed currents under different voltages. After the exposures, visual, scanning electron microscopy (SEM), X-ray diffraction (XRD) and corrosion rate analyses were performed. The results showed faster biofouling deposition on surfaces with a higher CP voltage, exposed to marine seawater, at the early stages. Subsequently, for longer exposure times, intermediate CP voltages offered less biofouling protection. XRD analyses showed the presence of calcareous compounds (calcite and aragonite), among others. Meanwhile, the corrosion observed in the laboratory was mediated by the amounts of deposited salts, with higher corrosion corresponding to higher CP voltages. Changes in temperature for the same CP voltage caused quantitative and qualitative differences in salt deposition. The higher Pb content of the CC492K alloy compared with the higher Cu and Sn contents of GR-10 did not manifest at the biofouling level, but different corrosion rates were measured (GR-10 < CC492K). Thus, the optimal CP protection conditions for marine and laboratory environments are not the same, because of the different conditions involved.

Authors

Institutions

Publication Details

Journal
Metals
Published
2026-08-18
DOI
https://doi.org/10.3390/met16080918
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of Cathodic Protection Effects on Corrosion and Biofouling of Bronze Alloys in Marine Environment and Laboratory Conditions

Berta Antelo, I. Braceras, Javier Franco, Aiala Urbegain et al.
Metals
Corrosion Behavior and Inhibition
article

Comparative Study of Cathodic Protection Effects on Corrosion and Biofouling of Bronze Alloys in Marine Environment and Laboratory Conditions

Berta Antelo, I. Braceras, Javier Franco, Aiala Urbegain, Carlos G. San-Gabino, Antonio Santiago
article en

Abstract

Cathodic protection (CP) is used in the marine industry to prevent corrosion of metal components in seawater but may also promote biofilm formation. When steel and copper alloy components are in contact, the latter is often subjected to higher applied CP voltages than otherwise required when a steel component is not present. In this study, the protection that CP offers in bronze alloys (RG-10 and CC492K) was assessed, both in controlled laboratory conditions and in real marine conditions in the Bay of Biscay (up to 3000 h), with various temperatures and methods: sacrificial anodes and impressed currents under different voltages. After the exposures, visual, scanning electron microscopy (SEM), X-ray diffraction (XRD) and corrosion rate analyses were performed. The results showed faster biofouling deposition on surfaces with a higher CP voltage, exposed to marine seawater, at the early stages. Subsequently, for longer exposure times, intermediate CP voltages offered less biofouling protection. XRD analyses showed the presence of calcareous compounds (calcite and aragonite), among others. Meanwhile, the corrosion observed in the laboratory was mediated by the amounts of deposited salts, with higher corrosion corresponding to higher CP voltages. Changes in temperature for the same CP voltage caused quantitative and qualitative differences in salt deposition. The higher Pb content of the CC492K alloy compared with the higher Cu and Sn contents of GR-10 did not manifest at the biofouling level, but different corrosion rates were measured (GR-10 < CC492K). Thus, the optimal CP protection conditions for marine and laboratory environments are not the same, because of the different conditions involved.

MetalsVol. 16(8)
University of the Basque Country (ES), Tecnalia (ES), Gobierno de Navarra (ES), Casa de Velázquez (ES), Marine Technology Unit (ES)
Life below water
Openalex Percentile: Top 22%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.