A MultifunctionalLasso-like Peptide-Based ElectrochemicalBiosensor: Overcoming Biofouling and Enzymatic Degradation for High-FidelityImmunoglobulin G Assay

Abstract The reliable electrochemical detection of immunoglobulin G (IgG) in complex biological fluids is severely hampered by nonspecific protein fouling and enzymatic degradation. Inspired by natural lasso peptides, we engineer a multifunctional lasso-like peptide (LaP) composed entirely of D-amino acids that uniquely integrates a terminal cysteine anchoring domain, a zwitterionic antifouling segment, and a specific IgG recognition segment into a single topology-constrained architecture. The covalently closed lasso topology sterically restricts protease access to cleavage-sensitive peptide bonds, while the all-D-amino acid backbone is inherently invisible to naturally occurring proteases. Together, these features provide dual physical and stereochemical protection while preserving the conformational freedom of the recognition domain for efficient target binding. Compared with a branched peptide (BrP) of identical sequence, the LaP-modified interface exhibits markedly superior resistance to nonspecific protein adsorption in undiluted serum. Molecular dynamics simulations reveal that the lasso constraint induces a superficial, low-affinity binding pose toward carboxypeptidase Y (CPY), whereas BrP penetrates deeply into the enzyme active pocket. Consequently, the LaP-based biosensor shows negligible signal change after CPY treatment, whereas BrP loses most of its activity. The LaP/AuNPs/PANI electrochemical biosensor achieves excellent selectivity and maintains its analytical performance even in complex serum matrices. This work establishes a paradigm for designing topology-constrained, multifunctional peptide interfaces that overcome the longstanding trade-off between biofouling and enzymatic degradation, opening new avenues for high-fidelity electrochemical biosensing in complex biological matrices.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-08-18
DOI
https://doi.org/10.1021/acs.analchem.6c04069
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A MultifunctionalLasso-like Peptide-Based ElectrochemicalBiosensor: Overcoming Biofouling and Enzymatic Degradation for High-FidelityImmunoglobulin G Assay

Yingshu Guo, Jiawei Pan, Nianzu Liu, Xiliang Luo et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

A MultifunctionalLasso-like Peptide-Based ElectrochemicalBiosensor: Overcoming Biofouling and Enzymatic Degradation for High-FidelityImmunoglobulin G Assay

Yingshu Guo, Jiawei Pan, Nianzu Liu, Xiliang Luo, Shuohan Lin, Yanlong Huang, Jingwen Xu
article en

Abstract

Abstract The reliable electrochemical detection of immunoglobulin G (IgG) in complex biological fluids is severely hampered by nonspecific protein fouling and enzymatic degradation. Inspired by natural lasso peptides, we engineer a multifunctional lasso-like peptide (LaP) composed entirely of D-amino acids that uniquely integrates a terminal cysteine anchoring domain, a zwitterionic antifouling segment, and a specific IgG recognition segment into a single topology-constrained architecture. The covalently closed lasso topology sterically restricts protease access to cleavage-sensitive peptide bonds, while the all-D-amino acid backbone is inherently invisible to naturally occurring proteases. Together, these features provide dual physical and stereochemical protection while preserving the conformational freedom of the recognition domain for efficient target binding. Compared with a branched peptide (BrP) of identical sequence, the LaP-modified interface exhibits markedly superior resistance to nonspecific protein adsorption in undiluted serum. Molecular dynamics simulations reveal that the lasso constraint induces a superficial, low-affinity binding pose toward carboxypeptidase Y (CPY), whereas BrP penetrates deeply into the enzyme active pocket. Consequently, the LaP-based biosensor shows negligible signal change after CPY treatment, whereas BrP loses most of its activity. The LaP/AuNPs/PANI electrochemical biosensor achieves excellent selectivity and maintains its analytical performance even in complex serum matrices. This work establishes a paradigm for designing topology-constrained, multifunctional peptide interfaces that overcome the longstanding trade-off between biofouling and enzymatic degradation, opening new avenues for high-fidelity electrochemical biosensing in complex biological matrices.

Analytical Chemistry
Qingdao University of Science and Technology (CN), Qilu University of Technology (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 16%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.