Comparative Orthogonal RP-UHPLC and SEC-UHPLC Methods for Quantitative Analysis and Integrity Assessment of Cetuximab-Based Antibody–Drug Conjugates

Antibody–drug conjugates (ADCs) are structurally complex biopharmaceuticals whose quantitative characterization is often complicated by payload-related interferences and molecular heterogeneity. In this study, two complementary chromatographic methods based on reverse-phase ultra-high-performance liquid chromatography (RP-UHPLC) and size-exclusion ultra-performance liquid chromatography (SEC-UHPLC) coupled with diode array detection were developed and comparatively evaluated for quantitative and integrity assessment of Cetuximab (CET) in ADC formulations. The RP-UHPLC method, developed on a C8 stationary phase under denaturing conditions, showed linearity over the range 0.05–5 mg/mL (R2 = 0.9979), with LOD and LOQ values of 10 and 40 μg/mL, respectively. The SEC-UHPLC method, optimized under native conditions on a Yarra SEC-3000 column, exhibited linearity within the 0.5–5 mg/mL range (R2 = 0.9998), with LOD and LOQ values of 17 and 52 μg/mL, respectively. Both methods showed satisfactory accuracy, precision, and robustness according to a fit-for-purpose validation approach. Application to CET-based ADCs bearing different aminobisphosphonate payloads confirmed reliable quantification. RP-UHPLC enabled sensitive determination of antibody concentration, whereas SEC-UHPLC enabled assessment of monomeric integrity and sample heterogeneity under native conditions. Comparative analysis of aged ADC samples demonstrated that SEC-UHPLC revealed loss of structural integrity and sample heterogeneity that were not detectable by RP-UHPLC or direct UV spectrophotometry. The combined RP-UHPLC/SEC-UHPLC workflow provides a robust, accessible, and complementary platform for routine quantitative analysis and integrity assessment of ADC formulations.

Authors

Institutions

Publication Details

Journal
Separations
Published
2026-08-18
DOI
https://doi.org/10.3390/separations13080236
Primary Topic
HER2/EGFR in Cancer Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Orthogonal RP-UHPLC and SEC-UHPLC Methods for Quantitative Analysis and Integrity Assessment of Cetuximab-Based Antibody–Drug Conjugates

Vincenzo Calderone, Maria Digiacomo, Lizzia Raffaghello, Roberto Benelli et al.
Separations
HER2/EGFR in Cancer Research
article

Comparative Orthogonal RP-UHPLC and SEC-UHPLC Methods for Quantitative Analysis and Integrity Assessment of Cetuximab-Based Antibody–Drug Conjugates

Vincenzo Calderone, Maria Digiacomo, Lizzia Raffaghello, Roberto Benelli, Elisa Nuti, Doretta Cuffaro, Enrico Crispino
article en

Abstract

Antibody–drug conjugates (ADCs) are structurally complex biopharmaceuticals whose quantitative characterization is often complicated by payload-related interferences and molecular heterogeneity. In this study, two complementary chromatographic methods based on reverse-phase ultra-high-performance liquid chromatography (RP-UHPLC) and size-exclusion ultra-performance liquid chromatography (SEC-UHPLC) coupled with diode array detection were developed and comparatively evaluated for quantitative and integrity assessment of Cetuximab (CET) in ADC formulations. The RP-UHPLC method, developed on a C8 stationary phase under denaturing conditions, showed linearity over the range 0.05–5 mg/mL (R2 = 0.9979), with LOD and LOQ values of 10 and 40 μg/mL, respectively. The SEC-UHPLC method, optimized under native conditions on a Yarra SEC-3000 column, exhibited linearity within the 0.5–5 mg/mL range (R2 = 0.9998), with LOD and LOQ values of 17 and 52 μg/mL, respectively. Both methods showed satisfactory accuracy, precision, and robustness according to a fit-for-purpose validation approach. Application to CET-based ADCs bearing different aminobisphosphonate payloads confirmed reliable quantification. RP-UHPLC enabled sensitive determination of antibody concentration, whereas SEC-UHPLC enabled assessment of monomeric integrity and sample heterogeneity under native conditions. Comparative analysis of aged ADC samples demonstrated that SEC-UHPLC revealed loss of structural integrity and sample heterogeneity that were not detectable by RP-UHPLC or direct UV spectrophotometry. The combined RP-UHPLC/SEC-UHPLC workflow provides a robust, accessible, and complementary platform for routine quantitative analysis and integrity assessment of ADC formulations.

SeparationsVol. 13(8)
University of Pisa (IT), Azienda Ospedaliera S.Maria (IT)
Openalex Percentile: Top 12%
HER2/EGFR in Cancer Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.