One-Pot, Two-Stage Synthesis of Carboxylate-Functionalized Fluorescent Polymer Nanoparticles for Ultrasensitive Fluorescent Lateral Flow Immunoassays

Abstract We have developed a one-pot, two-stage method for the synthesis of highly monodispersed fluorescent polystyrene nanoparticles with surface carboxyl functional groups. The fluorescent nanoparticles have a tunable size range of 150−300 nm and excellent photo/chemical stability. Through conjugating antibodies to the surface carboxyl groups, various lateral flow immunoassays (LFIAs) using the fluorescent nanoparticles as the reporters have been developed, achieving a visual limit of detection (LOD) of 39 mIU mL−1 using human chorionic gonadotropin as the model sample. This LOD is 8-fold and 64-fold better as compared to LFIAs using AuNPs and free dye as reporters, respectively. The LODs of our optimized LFIAs are 3 pg mL−1 for HIV-1 p24, 4 ng mL−1 for Zika NS1, and 1 and 0.5 ng mL−1 for Staphylococcus aureus enterotoxin types A and B, respectively. These LOD values are below the clinical cutoffs and are comparable to ELISA results reported in the literature.

Authors

Institutions

Publication Details

Journal
ACS Materials Letters
Published
2026-08-18
DOI
https://doi.org/10.1021/acsmaterialslett.6c00617
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Pot, Two-Stage Synthesis of Carboxylate-Functionalized Fluorescent Polymer Nanoparticles for Ultrasensitive Fluorescent Lateral Flow Immunoassays

Kian Ping Chan, Jackie Y. Ying, Jerry K. C. Toh, Jun Hui Soh et al.
ACS Materials Letters
Biosensors and Analytical Detection
article

One-Pot, Two-Stage Synthesis of Carboxylate-Functionalized Fluorescent Polymer Nanoparticles for Ultrasensitive Fluorescent Lateral Flow Immunoassays

Kian Ping Chan, Jackie Y. Ying, Jerry K. C. Toh, Jun Hui Soh, Xiaojun Chen
article en

Abstract

Abstract We have developed a one-pot, two-stage method for the synthesis of highly monodispersed fluorescent polystyrene nanoparticles with surface carboxyl functional groups. The fluorescent nanoparticles have a tunable size range of 150−300 nm and excellent photo/chemical stability. Through conjugating antibodies to the surface carboxyl groups, various lateral flow immunoassays (LFIAs) using the fluorescent nanoparticles as the reporters have been developed, achieving a visual limit of detection (LOD) of 39 mIU mL−1 using human chorionic gonadotropin as the model sample. This LOD is 8-fold and 64-fold better as compared to LFIAs using AuNPs and free dye as reporters, respectively. The LODs of our optimized LFIAs are 3 pg mL−1 for HIV-1 p24, 4 ng mL−1 for Zika NS1, and 1 and 0.5 ng mL−1 for Staphylococcus aureus enterotoxin types A and B, respectively. These LOD values are below the clinical cutoffs and are comparable to ELISA results reported in the literature.

ACS Materials Letters
Agency for Science, Technology and Research (SG), King Faisal Specialist Hospital & Research Centre (SA)
Openalex Percentile: Top 18%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

One-Pot, Two-Stage Synthesis of Carboxylate-Functionalized Fluorescent Polymer Nanoparticles for Ultrasensitive Fluorescent Lateral Flow Immunoassays — Kian Ping Chan, Jackie Y. Ying, et al. · ACS Materials Letters (2026) | TGRS Research Map | TGRS