Comparison of urodynamic outcomes by hysterectomy technique: A cross-sectional study

Although hysterectomy significantly alters pelvic anatomy, its long-term effects on bladder function, pelvic floor integrity, and urethral sphincter activity remain controversial. Previous studies have reported inconsistent findings, often limited by surgical variability, heterogeneous study populations, and differing definitions of detrusor hypocontractility. This study aimed to determine whether urodynamic results—specifically, detrusor contractility, urethral sphincter function, and pelvic floor function—differ according to hysterectomy technique. We conducted a retrospective, single-center, cross-sectional analysis of urodynamic studies from women who underwent abdominal, vaginal, or laparoscopic hysterectomy in Mexico between 2019 and 2024. Standardized thresholds derived from established urodynamic references were used to evaluate detrusor function, sphincter strength, and pelvic floor integrity. ANOVA, Kruskal–Wallis, and chi-square tests were applied ( p < 0.05). Among 172 women, 124 (72.1%) underwent abdominal hysterectomy, 40 (23.2%) vaginal, and 8 (4.6%) laparoscopic. No significant differences were found in pelvic floor function or urethral pressure profile across surgical types. However, patients undergoing vaginal hysterectomy more frequently demonstrated urodynamic findings consistent with detrusor hypocontractility, with lower Qmax and detrusor contraction index values. This is the first study to directly compare urodynamic parameters across hysterectomy techniques. Vaginal hysterectomy was associated with a higher prevalence of urodynamic findings consistent with detrusor hypocontractility, whereas urethral and pelvic floor function remained unaffected by surgical approach. Although the observed association does not imply causality, these findings support further investigation of the relationship between hysterectomy technique and postoperative bladder function, particularly in patients for whom vaginal hysterectomy is considered and who have known risk factors for detrusor hypocontractility.

Authors

Institutions

Publication Details

Journal
Urologia Journal
Published
2026-08-18
DOI
https://doi.org/10.1177/03915603261478158
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of urodynamic outcomes by hysterectomy technique: A cross-sectional study

Salvador Pizarro, Joel Herrera, Raymundo Alfonso Muñoz-Cabello, Alfonzo E. Munoz et al.
Urologia Journal
Pelvic floor disorders treatments
article

Comparison of urodynamic outcomes by hysterectomy technique: A cross-sectional study

Salvador Pizarro, Joel Herrera, Raymundo Alfonso Muñoz-Cabello, Alfonzo E. Munoz, Marlene Muñiz, Marcos Iglesias, José M. Arroyo
article en

Abstract

Although hysterectomy significantly alters pelvic anatomy, its long-term effects on bladder function, pelvic floor integrity, and urethral sphincter activity remain controversial. Previous studies have reported inconsistent findings, often limited by surgical variability, heterogeneous study populations, and differing definitions of detrusor hypocontractility. This study aimed to determine whether urodynamic results—specifically, detrusor contractility, urethral sphincter function, and pelvic floor function—differ according to hysterectomy technique. We conducted a retrospective, single-center, cross-sectional analysis of urodynamic studies from women who underwent abdominal, vaginal, or laparoscopic hysterectomy in Mexico between 2019 and 2024. Standardized thresholds derived from established urodynamic references were used to evaluate detrusor function, sphincter strength, and pelvic floor integrity. ANOVA, Kruskal–Wallis, and chi-square tests were applied ( p < 0.05). Among 172 women, 124 (72.1%) underwent abdominal hysterectomy, 40 (23.2%) vaginal, and 8 (4.6%) laparoscopic. No significant differences were found in pelvic floor function or urethral pressure profile across surgical types. However, patients undergoing vaginal hysterectomy more frequently demonstrated urodynamic findings consistent with detrusor hypocontractility, with lower Qmax and detrusor contraction index values. This is the first study to directly compare urodynamic parameters across hysterectomy techniques. Vaginal hysterectomy was associated with a higher prevalence of urodynamic findings consistent with detrusor hypocontractility, whereas urethral and pelvic floor function remained unaffected by surgical approach. Although the observed association does not imply causality, these findings support further investigation of the relationship between hysterectomy technique and postoperative bladder function, particularly in patients for whom vaginal hysterectomy is considered and who have known risk factors for detrusor hypocontractility.

Urologia Journal
Autonomous University of Chihuahua (MX), Houston Fertility Institute (US), Guhua Hospital (CN), University of Monterrey (MX)
Good health and well-being
Openalex Percentile: Top 9%
Pelvic floor disorders treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.