An Absorption-Based PDMS/f-CNT Mass-Capacitor for Continuous Monitoring of Fire-Derived Organic Contamination

Firefighters are exposed to complex smoke containing volatile, semivolatile, aromatic, and particulate-associated organic contaminants that accumulate on skin, clothing, and protective equipment. Conventional gas sensors monitor only selected airborne species, while passive samplers require laboratory analysis and cannot provide continuous exposure assessment. To address this limitation, we developed a proof-of-concept mass-capacitor that integrates contaminant absorption and electrical sensing within a single polydimethylsiloxane/functionalized carbon nanotube (PDMS/f-CNT) composite coated on interdigitated electrodes (IDEs). Unlike conventional sensors that report the instantaneous concentration of selected compounds, the proposed platform functions as both a sorptive collector and an electrical transducer. It continuously converts contaminant uptake, retention, and release into a time-resolved electrical response. For firefighter applications, this mass-capacitor bridges the gap between passive sorptive samplers and conventional real-time gas sensors. It enables continuous tracking of the cumulative sorbed contamination burden without requiring offline laboratory analysis or restricting the measurement to selected airborne species. A custom potentiostat applied staircase cyclic excitation, while Fast Fourier Transform (FFT)-assisted processing enabled extraction of the differential charge, ΔQ as an indicator of contaminant loading. The sensor was evaluated using smoke generated from cotton, paper, wood, and synthetic fibers. Compared with PDMS alone, the PDMS/f-CNT composite produced an approximately 24-fold higher response with minimal humidity interference (≈80% RH). Limits of detection ranged from 0.08 to 0.26 ppm, while repeated smoke exposures produced stepwise increases in ΔQ, demonstrating continuous tracking of cumulative contaminant loading. These results establish the feasibility of the mass-capacitor concept and introduce a new approach for real-time monitoring of the accumulated organic contamination burden rather than the instantaneous concentration of individual airborne compounds.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-18
DOI
https://doi.org/10.3390/s26165220
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Absorption-Based PDMS/f-CNT Mass-Capacitor for Continuous Monitoring of Fire-Derived Organic Contamination

Morteza Ghafar-Zadeh, Sebastian Magierowski, Ebrahim Ghafar‐Zadeh, Parviz Norouzi et al.
Sensors
Advanced Sensor and Energy Harvesting Materials
article

An Absorption-Based PDMS/f-CNT Mass-Capacitor for Continuous Monitoring of Fire-Derived Organic Contamination

Morteza Ghafar-Zadeh, Sebastian Magierowski, Ebrahim Ghafar‐Zadeh, Parviz Norouzi, Azadeh Amrollahi, Negar Heidari
article en

Abstract

Firefighters are exposed to complex smoke containing volatile, semivolatile, aromatic, and particulate-associated organic contaminants that accumulate on skin, clothing, and protective equipment. Conventional gas sensors monitor only selected airborne species, while passive samplers require laboratory analysis and cannot provide continuous exposure assessment. To address this limitation, we developed a proof-of-concept mass-capacitor that integrates contaminant absorption and electrical sensing within a single polydimethylsiloxane/functionalized carbon nanotube (PDMS/f-CNT) composite coated on interdigitated electrodes (IDEs). Unlike conventional sensors that report the instantaneous concentration of selected compounds, the proposed platform functions as both a sorptive collector and an electrical transducer. It continuously converts contaminant uptake, retention, and release into a time-resolved electrical response. For firefighter applications, this mass-capacitor bridges the gap between passive sorptive samplers and conventional real-time gas sensors. It enables continuous tracking of the cumulative sorbed contamination burden without requiring offline laboratory analysis or restricting the measurement to selected airborne species. A custom potentiostat applied staircase cyclic excitation, while Fast Fourier Transform (FFT)-assisted processing enabled extraction of the differential charge, ΔQ as an indicator of contaminant loading. The sensor was evaluated using smoke generated from cotton, paper, wood, and synthetic fibers. Compared with PDMS alone, the PDMS/f-CNT composite produced an approximately 24-fold higher response with minimal humidity interference (≈80% RH). Limits of detection ranged from 0.08 to 0.26 ppm, while repeated smoke exposures produced stepwise increases in ΔQ, demonstrating continuous tracking of cumulative contaminant loading. These results establish the feasibility of the mass-capacitor concept and introduce a new approach for real-time monitoring of the accumulated organic contamination burden rather than the instantaneous concentration of individual airborne compounds.

SensorsVol. 26(16)
York University (CA)
Openalex Percentile: Top 18%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.