Visual Outcomes, Intraocular Pressure Changes, and Complications Following Nd:YAG (Neodymium-Doped Yttrium Aluminum Garnet) Laser Posterior Capsulotomy for Posterior Capsular Opacification: A Prospective Clinical Study

Aims and backgrounds Posterior capsular opacification (PCO) is the most common long-term complication after cataract surgery. It leads to decreased contrast sensitivity, distracting glare, and impaired vision. The neodymium-doped yttrium aluminum garnet (Nd:YAG) laser posterior capsulotomy is the de facto standard for non-invasive treatment of visually significant PCO. It enables rapid vision recovery and is considered a gold standard procedure. Nevertheless, complications including increased intraocular pressure (IOP), cystoid macular edema (CME), and retinal detachment are possible following the procedure. Methods Prospective observational research was done at a tertiary care center in Vadodara, Gujarat. Patients with PCO undergoing Nd:YAG laser capsulotomy were included based on defined inclusion and exclusion criteria. Intraocular pressure (IOP), slit lamp examination, dilated fundus examination, uncorrected and best-corrected visual acuity (UCVA, BCVA), and intraocular pressure (IOP) were all part of the pre- and post-procedure measurements. Complications such as CME, retinal detachment, iritis, and IOP rise were recorded. The relationship between total laser energy used and IOP changes was also assessed. Results Most patients achieved rapid, significant visual improvement. Transient IOP elevations were infrequent and medically manageable, with higher risks linked to increased cumulative laser energy. Severe complications like CME were rare. Conclusion Nd:YAG laser capsulotomy is a safe, effective outpatient procedure. Optimal energy settings and post-operative monitoring are vital to maximize recovery and minimize complications. Clinical significance To ensure optimal outcomes and minimize risks, clinicians should use the minimum effective laser energy, ensure precise focusing, and routinely monitor post-procedural intraocular pressure.

Authors

Publication Details

Journal
Cureus
Published
2026-08-18
DOI
https://doi.org/10.7759/cureus.114720
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual Outcomes, Intraocular Pressure Changes, and Complications Following Nd:YAG (Neodymium-Doped Yttrium Aluminum Garnet) Laser Posterior Capsulotomy for Posterior Capsular Opacification: A Prospective Clinical Study

Nikhil Gore, Sujata Charel
Cureus
Intraocular Surgery and Lenses
article

Visual Outcomes, Intraocular Pressure Changes, and Complications Following Nd:YAG (Neodymium-Doped Yttrium Aluminum Garnet) Laser Posterior Capsulotomy for Posterior Capsular Opacification: A Prospective Clinical Study

Nikhil Gore, Sujata Charel
article en

Abstract

Aims and backgrounds Posterior capsular opacification (PCO) is the most common long-term complication after cataract surgery. It leads to decreased contrast sensitivity, distracting glare, and impaired vision. The neodymium-doped yttrium aluminum garnet (Nd:YAG) laser posterior capsulotomy is the de facto standard for non-invasive treatment of visually significant PCO. It enables rapid vision recovery and is considered a gold standard procedure. Nevertheless, complications including increased intraocular pressure (IOP), cystoid macular edema (CME), and retinal detachment are possible following the procedure. Methods Prospective observational research was done at a tertiary care center in Vadodara, Gujarat. Patients with PCO undergoing Nd:YAG laser capsulotomy were included based on defined inclusion and exclusion criteria. Intraocular pressure (IOP), slit lamp examination, dilated fundus examination, uncorrected and best-corrected visual acuity (UCVA, BCVA), and intraocular pressure (IOP) were all part of the pre- and post-procedure measurements. Complications such as CME, retinal detachment, iritis, and IOP rise were recorded. The relationship between total laser energy used and IOP changes was also assessed. Results Most patients achieved rapid, significant visual improvement. Transient IOP elevations were infrequent and medically manageable, with higher risks linked to increased cumulative laser energy. Severe complications like CME were rare. Conclusion Nd:YAG laser capsulotomy is a safe, effective outpatient procedure. Optimal energy settings and post-operative monitoring are vital to maximize recovery and minimize complications. Clinical significance To ensure optimal outcomes and minimize risks, clinicians should use the minimum effective laser energy, ensure precise focusing, and routinely monitor post-procedural intraocular pressure.

Cureus
Openalex Percentile: Top 7%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual Outcomes, Intraocular Pressure Changes, and Complications Following Nd:YAG (Neodymium-Doped Yttrium Aluminum Garnet) Laser Posterior Capsulotomy for Posterior Capsular Opacification: A Prospective Clinical Study — Nikhil Gore, Sujata Charel · Cureus (2026) | TGRS Research Map | TGRS