Stepwise Electrosurgical Bailout During Difficult Left Bundle Branch Area Pacing

Electrosurgical energy may facilitate difficult septal lead advancement during left bundle branch area pacing (LBBAP), but procedural feedback after each application is poorly defined. A 63-year-old woman with complete atrioventricular block had persistent left ventricular septal pacing (LVSP) despite deep septal engagement and prolonged mechanical rotation. Two brief 20-W AUTO CUT cycles were delivered through a stylet-driven pacing lead. The first was followed by no meaningful COI or mechanical change. The second was followed by a decrease in COI and renewed lead advancement. Output decrement subsequently demonstrated transition from nonselective to selective LBB capture, with S-V separation of 25 ms and shortening of V6 R-wave peak time from 90 to 73 ms.One-month imaging and electrical parameters remained stable.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-08-18
DOI
https://doi.org/10.1111/pace.70403
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stepwise Electrosurgical Bailout During Difficult Left Bundle Branch Area Pacing

Longfu Jiang, Binbin Luo, Yue Zhang, Di Lu et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Stepwise Electrosurgical Bailout During Difficult Left Bundle Branch Area Pacing

Longfu Jiang, Binbin Luo, Yue Zhang, Di Lu, Guofang Chen
article en

Abstract

Electrosurgical energy may facilitate difficult septal lead advancement during left bundle branch area pacing (LBBAP), but procedural feedback after each application is poorly defined. A 63-year-old woman with complete atrioventricular block had persistent left ventricular septal pacing (LVSP) despite deep septal engagement and prolonged mechanical rotation. Two brief 20-W AUTO CUT cycles were delivered through a stylet-driven pacing lead. The first was followed by no meaningful COI or mechanical change. The second was followed by a decrease in COI and renewed lead advancement. Output decrement subsequently demonstrated transition from nonselective to selective LBB capture, with S-V separation of 25 ms and shortening of V6 R-wave peak time from 90 to 73 ms.One-month imaging and electrical parameters remained stable.

Pacing and Clinical Electrophysiology
Ningbo University (CN), Wenzhou Medical University (CN)
Affordable and clean energy
Openalex Percentile: Top 9%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.