Monitoring the Shear Behavior of Reinforced Concrete Beams Using Fiber Optic Sensors Installed in the Compression Zone

A variety of measurement systems are available for monitoring existing concrete bridges with deficiencies in shear capacity. In addition to established systems, fiber optic sensors (FOS) offer significant potential for structural health monitoring. However, FOSs are often installed in the tension zone, where crack formation may occur even under service loads, increasing the risk of sensor failure and potentially resulting in a loss of measurement capability. A promising approach to significantly reduce this risk is the installation of FOSs in the compression zone. However, it remains unclear whether measurements obtained from FOSs in the compression zone can be used to assess the load-bearing and deformation behavior of reinforced concrete beams and how they relate to measurements obtained in the tension zone. To address this question, shear tests were carried out on reinforced concrete beams with shear reinforcement ratios commonly used in practice. The experimental results demonstrate close agreement between measurements obtained from FOSs installed in the compression and tension zones under service loads. Furthermore, the findings and the characteristic strain profiles associated with shear and flexural failure provide a basis for assessing existing structures monitored using FOSs.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-18
DOI
https://doi.org/10.3390/s26165226
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring the Shear Behavior of Reinforced Concrete Beams Using Fiber Optic Sensors Installed in the Compression Zone

Vincent Oettel, Johannes Rathgen
Sensors
Advanced Fiber Optic Sensors
article

Monitoring the Shear Behavior of Reinforced Concrete Beams Using Fiber Optic Sensors Installed in the Compression Zone

Vincent Oettel, Johannes Rathgen
article en

Abstract

A variety of measurement systems are available for monitoring existing concrete bridges with deficiencies in shear capacity. In addition to established systems, fiber optic sensors (FOS) offer significant potential for structural health monitoring. However, FOSs are often installed in the tension zone, where crack formation may occur even under service loads, increasing the risk of sensor failure and potentially resulting in a loss of measurement capability. A promising approach to significantly reduce this risk is the installation of FOSs in the compression zone. However, it remains unclear whether measurements obtained from FOSs in the compression zone can be used to assess the load-bearing and deformation behavior of reinforced concrete beams and how they relate to measurements obtained in the tension zone. To address this question, shear tests were carried out on reinforced concrete beams with shear reinforcement ratios commonly used in practice. The experimental results demonstrate close agreement between measurements obtained from FOSs installed in the compression and tension zones under service loads. Furthermore, the findings and the characteristic strain profiles associated with shear and flexural failure provide a basis for assessing existing structures monitored using FOSs.

SensorsVol. 26(16)
Technische Universität Braunschweig (DE)
Sustainable cities and communities
Openalex Percentile: Top 18%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.