Titanium Dioxide Nanoparticles Modified Carbon Paste Electrode for Redox Process Application

TiO2-NPs were synthesized by the SolGel procedure and characterised using a mixture of graphite powder and paraffin oil to create a homogeneous black-sensitive Titanium dioxide nanoparticle carbon paste electrode (TiO2-NPs-CPE). The best conductivity was studied by using a variety of mixture ratios, 30:70, 50:50 and 70:30, and the results refer to 50:50 as the best TiO2: graphite mixture ratio. The Redox processes were applied by Potentiostat cyclic voltammetry to mutate the trace current by electron migration. Scan rate, temperature and pH conditions studied and the result recorded (0.1 vs–1, [288-308] K and 6-7) respectively, is the best condition for electrode determination. (LOD) and (LOQ) selected with a high aquic calibration curve range (1-10) ppm used for detecting the unknown titanium ions solutions, and physical parameters (DG, DH, DS and K) were calculated (1.5, 1.2, 3.1 and 0.1) respectively (DG, DH, DS and K

Authors

Institutions

Publication Details

Journal
Baghdad Science Journal
Published
2026-08-17
DOI
https://doi.org/10.21123/2411-7986.5382
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Titanium Dioxide Nanoparticles Modified Carbon Paste Electrode for Redox Process Application

Emad Salaam Abood
Baghdad Science Journal
Water Quality Monitoring and Analysis
article

Titanium Dioxide Nanoparticles Modified Carbon Paste Electrode for Redox Process Application

Emad Salaam Abood
article en

Abstract

TiO2-NPs were synthesized by the SolGel procedure and characterised using a mixture of graphite powder and paraffin oil to create a homogeneous black-sensitive Titanium dioxide nanoparticle carbon paste electrode (TiO2-NPs-CPE). The best conductivity was studied by using a variety of mixture ratios, 30:70, 50:50 and 70:30, and the results refer to 50:50 as the best TiO2: graphite mixture ratio. The Redox processes were applied by Potentiostat cyclic voltammetry to mutate the trace current by electron migration. Scan rate, temperature and pH conditions studied and the result recorded (0.1 vs–1, [288-308] K and 6-7) respectively, is the best condition for electrode determination. (LOD) and (LOQ) selected with a high aquic calibration curve range (1-10) ppm used for detecting the unknown titanium ions solutions, and physical parameters (DG, DH, DS and K) were calculated (1.5, 1.2, 3.1 and 0.1) respectively (DG, DH, DS and K

Baghdad Science JournalVol. 23(8)
University of Babylon (IQ)
Openalex Percentile: Top 9%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.