Artificial Intelligence Standardizes Pericoronary Fat Attenuation Index Measurement: External Multi-Vendor CT Validation

OBJECTIVES: To evaluate the feasibility and generalizability of an AI-based automated method for measuring the pericoronary fat attenuation index (FAI)-a promising non-invasive imaging biomarker for coronary inflammation-and to promote efficient clinical translation. METHODS: A retrospective analysis was conducted on coronary computed tomography angiography data from 1,125 patients (584 [51.9%] male; mean age 61.5 ± 12.3 years; totaling 3,375 coronary arteries) examined using five mainstream CT scanners from different manufacturers, models, and generations. FAI values around the major coronary arteries were quantitatively evaluated using both AI software and workstation. Agreement between methods, diagnostic performance, and scanner influence were assessed. RESULTS: Artificial intelligence-based fat attenuation index (AI-FAI) demonstrated a favorable correlation with workstation-FAI at the patient level (ρ = 0.877, p < 0.001; n = 1,125), along with a high level of agreement (mean bias: 1.60 HU; 95% limits of agreement: -4.94 to 8.14; 94.84% within limits). Using a threshold of -70.1 HU, AI-FAI demonstrated performance comparable to workstation-FAI, with accuracy (84.98%) and solid diagnostic performance (AUC = 0.851). Furthermore, AI-FAI exhibited stable measurement performance across all five scanners, with inter-scanner ρ ranging from 0.829 to 0.896 and only 3.70-6.06% of outliers beyond the agreement limits. CONCLUSIONS: AI-FAI demonstrates favorable agreement with traditional workstation-FAI, solid diagnostic performance, and consistent cross-scanner robustness, providing a reliable automated tool for cardiovascular risk assessment. ADVANCES IN KNOWLEDGE: This is a novel study demonstrating AI-FAI as a practical alternative to workstation-FAI across multiple CT scanners, facilitating reliable quantification of coronary inflammation for routine clinical practice.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-08-17
DOI
https://doi.org/10.1093/bjr/tqag186
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence Standardizes Pericoronary Fat Attenuation Index Measurement: External Multi-Vendor CT Validation

Linli Chen, Lan Wu, Zhede Zhao, Jie Xu et al.
British Journal of Radiology
Cardiovascular Disease and Adiposity
article

Artificial Intelligence Standardizes Pericoronary Fat Attenuation Index Measurement: External Multi-Vendor CT Validation

Linli Chen, Lan Wu, Zhede Zhao, Jie Xu, Ling Qiu
article en

Abstract

OBJECTIVES: To evaluate the feasibility and generalizability of an AI-based automated method for measuring the pericoronary fat attenuation index (FAI)-a promising non-invasive imaging biomarker for coronary inflammation-and to promote efficient clinical translation. METHODS: A retrospective analysis was conducted on coronary computed tomography angiography data from 1,125 patients (584 [51.9%] male; mean age 61.5 ± 12.3 years; totaling 3,375 coronary arteries) examined using five mainstream CT scanners from different manufacturers, models, and generations. FAI values around the major coronary arteries were quantitatively evaluated using both AI software and workstation. Agreement between methods, diagnostic performance, and scanner influence were assessed. RESULTS: Artificial intelligence-based fat attenuation index (AI-FAI) demonstrated a favorable correlation with workstation-FAI at the patient level (ρ = 0.877, p < 0.001; n = 1,125), along with a high level of agreement (mean bias: 1.60 HU; 95% limits of agreement: -4.94 to 8.14; 94.84% within limits). Using a threshold of -70.1 HU, AI-FAI demonstrated performance comparable to workstation-FAI, with accuracy (84.98%) and solid diagnostic performance (AUC = 0.851). Furthermore, AI-FAI exhibited stable measurement performance across all five scanners, with inter-scanner ρ ranging from 0.829 to 0.896 and only 3.70-6.06% of outliers beyond the agreement limits. CONCLUSIONS: AI-FAI demonstrates favorable agreement with traditional workstation-FAI, solid diagnostic performance, and consistent cross-scanner robustness, providing a reliable automated tool for cardiovascular risk assessment. ADVANCES IN KNOWLEDGE: This is a novel study demonstrating AI-FAI as a practical alternative to workstation-FAI across multiple CT scanners, facilitating reliable quantification of coronary inflammation for routine clinical practice.

British Journal of Radiology
Dalian Medical University (CN), Second Affiliated Hospital of Chongqing Medical University (CN), Mental Health Commission (IE), Chongqing Municipal Health Commission (CN), Tianjin Beichen Hospital (CN), Chongqing Medical University (CN)
Openalex Percentile: Top 10%
Cardiovascular Disease and Adiposity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.