Integration of Electromagnetic Field simulation and Axial Scalable Context Adaptive Frilled Lizard Reverse Graph Attention networks framework for high-fidelity non-ionizing brain tumor imaging

The growing demand for safe and high-resolution medical diagnostics has accelerated the adoption of non-ionizing imaging modalities, particularly Electromagnetic Field (EMF)-based brain tumor imaging, which enables radiation-free visualization with enhanced tissue differentiation. Despite these advantages, conventional EMF imaging systems suffer from low sensitivity to weak signals, suboptimal reflection and transmission coefficients, and high computational complexity, leading to reduced diagnostic accuracy. To address these limitations, this paper proposes an integrated framework combining Electromagnetic Field Simulation with an Axial Scalable Context Adaptive Frilled Lizard Reverse Graph Attention Network (Axial-SCAF-LRGAN). The proposed model synergistically incorporates a Scalable and Adaptive Graph Neural Network and a Context Axial Reverse Attention Network to effectively capture contextual and spatial dependencies, while the Frilled Lizard Optimization algorithm is employed for optimal parameter tuning and enhanced learning efficiency. Experimental evaluations demonstrate superior electromagnetic performance, achieving a gain of 9.86 dBi, a reflection coefficient S11 of -37.42 dB, and a transmission coefficient S21 of -22.18 dB, indicating minimal reflection losses and efficient signal transmission. Computational analysis further reveals a low processing time of 0.29 s, RMSE of 2.41, and correlation coefficient of 0.99, reflecting high predictive consistency. The framework attains an accuracy of 99.8%, sensitivity of 99.7%, specificity of 99.6%, and F1-score of 99.75%, confirming its effectiveness for efficient, non-invasive brain tumor imaging with enhanced clinical applicability.

Authors

Institutions

Publication Details

Journal
Electromagnetic Biology and Medicine
Published
2026-08-17
DOI
https://doi.org/10.1080/15368378.2026.2710711
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of Electromagnetic Field simulation and Axial Scalable Context Adaptive Frilled Lizard Reverse Graph Attention networks framework for high-fidelity non-ionizing brain tumor imaging

Badri Narayanan D, B. Raja Sekhar Reddy, Badiganchela Shiva Kumar, Kavitha V P et al.
Electromagnetic Biology and Medicine
Microwave Imaging and Scattering Analysis
article

Integration of Electromagnetic Field simulation and Axial Scalable Context Adaptive Frilled Lizard Reverse Graph Attention networks framework for high-fidelity non-ionizing brain tumor imaging

Badri Narayanan D, B. Raja Sekhar Reddy, Badiganchela Shiva Kumar, Kavitha V P, Mohandass G, Shirisha J
article en

Abstract

The growing demand for safe and high-resolution medical diagnostics has accelerated the adoption of non-ionizing imaging modalities, particularly Electromagnetic Field (EMF)-based brain tumor imaging, which enables radiation-free visualization with enhanced tissue differentiation. Despite these advantages, conventional EMF imaging systems suffer from low sensitivity to weak signals, suboptimal reflection and transmission coefficients, and high computational complexity, leading to reduced diagnostic accuracy. To address these limitations, this paper proposes an integrated framework combining Electromagnetic Field Simulation with an Axial Scalable Context Adaptive Frilled Lizard Reverse Graph Attention Network (Axial-SCAF-LRGAN). The proposed model synergistically incorporates a Scalable and Adaptive Graph Neural Network and a Context Axial Reverse Attention Network to effectively capture contextual and spatial dependencies, while the Frilled Lizard Optimization algorithm is employed for optimal parameter tuning and enhanced learning efficiency. Experimental evaluations demonstrate superior electromagnetic performance, achieving a gain of 9.86 dBi, a reflection coefficient S11 of -37.42 dB, and a transmission coefficient S21 of -22.18 dB, indicating minimal reflection losses and efficient signal transmission. Computational analysis further reveals a low processing time of 0.29 s, RMSE of 2.41, and correlation coefficient of 0.99, reflecting high predictive consistency. The framework attains an accuracy of 99.8%, sensitivity of 99.7%, specificity of 99.6%, and F1-score of 99.75%, confirming its effectiveness for efficient, non-invasive brain tumor imaging with enhanced clinical applicability.

Electromagnetic Biology and Medicine
SRM Institute of Science and Technology (IN), Sri Venkateswara University (IN), Maldives National University (MV), Department of Higher Education (IN), Saveetha University (IN)
Openalex Percentile: Top 18%
Microwave Imaging and Scattering Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.