3D-printed patient-specific instrumentation significantly improves the accuracy of prosthesis alignment in unicompartmental knee arthroplasty: a retrospective study

Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment knee osteoarthritis, with its outcomes highly dependent on the accuracy of prosthesis positioning. Conventional UKA, performed using traditional instrumentation, often relies heavily on surgical experience and may lead to variability in alignment. The emergence of 3D-printed patient-specific instrumentation (PSI) offers a promising approach to improve prosthesis placement accuracy and operational reproducibility. This study aims to evaluate the postoperative prosthesis position and short-term clinical outcomes of UKA assisted by 3D-printed PSI. A retrospective analysis was conducted on 22 patients (25 knees) who underwent PSI-guided UKA between May 2023 and May 2024. These were compared with 25 patients (31 knees) undergoing conventional UKA during the same period. Postoperative radiographic assessments included prosthesis position, limb alignment, and range of motion (ROM) in the sagittal plane. Clinical outcomes were evaluated using functional scores. Both groups showed significant improvement in limb alignment and knee function postoperatively ( p < 0.05), with no significant difference in preoperative and postoperative FTA within or between groups. The PSI group demonstrated superior outcomes in AKS-K score (91.7 ± 8.2 vs. 85.5 ± 6.9) and ROM (128.6° ± 9.4° vs. 120.3° ± 7.4°) compared to the control group ( p < 0.05). Prosthesis positioning was significantly more accurate in the PSI group regarding coronal and sagittal alignment of both tibial and femoral components ( p < 0.05). No significant difference was found in joint line height restoration. 3D-printed PSI significantly enhances the accuracy of prosthesis positioning in UKA, reduces operative time, and lowers the learning curve for less-experienced surgeons. Its core value lies in translating complex biomechanical requirements into standardized, executable surgical plans, thereby minimizing outliers in key alignment parameters.

Authors

Institutions

Publication Details

Journal
3D Printing in Medicine
Published
2026-08-17
DOI
https://doi.org/10.1186/s41205-026-00339-5
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-printed patient-specific instrumentation significantly improves the accuracy of prosthesis alignment in unicompartmental knee arthroplasty: a retrospective study

Jinhua Zhang, Xiangyu Meng, Zhuoli Li, Na Shen et al.
3D Printing in Medicine
Total Knee Arthroplasty Outcomes
article

3D-printed patient-specific instrumentation significantly improves the accuracy of prosthesis alignment in unicompartmental knee arthroplasty: a retrospective study

Jinhua Zhang, Xiangyu Meng, Zhuoli Li, Na Shen, Shang Gao, Kun Zhang, Peng Sun
article en

Abstract

Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment knee osteoarthritis, with its outcomes highly dependent on the accuracy of prosthesis positioning. Conventional UKA, performed using traditional instrumentation, often relies heavily on surgical experience and may lead to variability in alignment. The emergence of 3D-printed patient-specific instrumentation (PSI) offers a promising approach to improve prosthesis placement accuracy and operational reproducibility. This study aims to evaluate the postoperative prosthesis position and short-term clinical outcomes of UKA assisted by 3D-printed PSI. A retrospective analysis was conducted on 22 patients (25 knees) who underwent PSI-guided UKA between May 2023 and May 2024. These were compared with 25 patients (31 knees) undergoing conventional UKA during the same period. Postoperative radiographic assessments included prosthesis position, limb alignment, and range of motion (ROM) in the sagittal plane. Clinical outcomes were evaluated using functional scores. Both groups showed significant improvement in limb alignment and knee function postoperatively ( p < 0.05), with no significant difference in preoperative and postoperative FTA within or between groups. The PSI group demonstrated superior outcomes in AKS-K score (91.7 ± 8.2 vs. 85.5 ± 6.9) and ROM (128.6° ± 9.4° vs. 120.3° ± 7.4°) compared to the control group ( p < 0.05). Prosthesis positioning was significantly more accurate in the PSI group regarding coronal and sagittal alignment of both tibial and femoral components ( p < 0.05). No significant difference was found in joint line height restoration. 3D-printed PSI significantly enhances the accuracy of prosthesis positioning in UKA, reduces operative time, and lowers the learning curve for less-experienced surgeons. Its core value lies in translating complex biomechanical requirements into standardized, executable surgical plans, thereby minimizing outliers in key alignment parameters.

3D Printing in Medicine
Longgang Central Hospital (CN), ShenZhen People’s Hospital (CN), 82th Hospital of Pla (CN)
Openalex Percentile: Top 7%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.