Using a Consensus Reference Standard to Achieve High Reliability in Grading Aortic Stenosis in an Academic Pediatric Echo Lab

Accuracy and reliability are important in grading aortic stenosis (AS) by echocardiogram. There are no pediatric-specific consensus guidelines for grading AS by echo. Our objective was to adopt a consensus reference standard for AS and evaluate resulting interrater reliability in a pediatric echo laboratory. A reference standard for grading AS was derived from published adult guidelines. Measurements for mean gradient and aortic valve area as determined by the continuity equation were included. Comparisons were made between AS grades on 20 historic echo reports and AS grades using the new reference standard. Additionally, 6 readers used the reference standard to grade 10 studies prospectively and interrater reliability was evaluated for measurements required for grading AS and overall AS grade. Twenty echo studies were included (median subject age 7 IQR 4-16 years, median weight 32.2 IQR 13.8-44.8 kg). AS grade on historic echo reports and AS grade using new reference standard were in agreement 85% of the time. In the prospective portion of the study there was substantial agreement between raters on overall AS grade (Fleiss' kappa statistic 0.76 95% CI 0.54-0.98). There was excellent interrater reliability in measures of peak gradient (ICC 0.92, 95% CI 0.82-0.98), mean gradient (ICC 0.95, 95% CI 0.88-0.98), left ventricular outflow tract diameter (ICC 0.96, 95% CI 0.92-0.99), and left ventricular outflow tract velocity time integral (ICC 0.94, 95% CI 0.75-0.99). Using a consensus reference standard for grading AS may result in high interrater reliability in pediatric echo labs. Measurements of the mean gradient and measurements needed for the continuity equation for aortic valve area have high interrater reliability.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2026-08-17
DOI
https://doi.org/10.1007/s00246-026-04408-8
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using a Consensus Reference Standard to Achieve High Reliability in Grading Aortic Stenosis in an Academic Pediatric Echo Lab

Bethan Lemley, Angira Patel, Shivani Patel, Peter Koenig et al.
Pediatric Cardiology
Cardiac Valve Diseases and Treatments
article

Using a Consensus Reference Standard to Achieve High Reliability in Grading Aortic Stenosis in an Academic Pediatric Echo Lab

Bethan Lemley, Angira Patel, Shivani Patel, Peter Koenig, Pei-Ni Jone, Joshua Robinson
article en

Abstract

Accuracy and reliability are important in grading aortic stenosis (AS) by echocardiogram. There are no pediatric-specific consensus guidelines for grading AS by echo. Our objective was to adopt a consensus reference standard for AS and evaluate resulting interrater reliability in a pediatric echo laboratory. A reference standard for grading AS was derived from published adult guidelines. Measurements for mean gradient and aortic valve area as determined by the continuity equation were included. Comparisons were made between AS grades on 20 historic echo reports and AS grades using the new reference standard. Additionally, 6 readers used the reference standard to grade 10 studies prospectively and interrater reliability was evaluated for measurements required for grading AS and overall AS grade. Twenty echo studies were included (median subject age 7 IQR 4-16 years, median weight 32.2 IQR 13.8-44.8 kg). AS grade on historic echo reports and AS grade using new reference standard were in agreement 85% of the time. In the prospective portion of the study there was substantial agreement between raters on overall AS grade (Fleiss' kappa statistic 0.76 95% CI 0.54-0.98). There was excellent interrater reliability in measures of peak gradient (ICC 0.92, 95% CI 0.82-0.98), mean gradient (ICC 0.95, 95% CI 0.88-0.98), left ventricular outflow tract diameter (ICC 0.96, 95% CI 0.92-0.99), and left ventricular outflow tract velocity time integral (ICC 0.94, 95% CI 0.75-0.99). Using a consensus reference standard for grading AS may result in high interrater reliability in pediatric echo labs. Measurements of the mean gradient and measurements needed for the continuity equation for aortic valve area have high interrater reliability.

Pediatric Cardiology
Northwestern University (US), Lurie Children's Hospital (US)
Quality Education
Openalex Percentile: Top 10%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.