Initial PerformanceEvaluation of an Ultraviolet 157nm Laser Ablation System for ICP–MS Analysis

Abstract Laser wavelength largely governs analytical accuracy in laser ablation microanalysis. Most routine laser ablation systems rely on 193 nm excimer lasers, while the considerably shorter 157 nm wavelength has only been applied sparingly to in situ microanalysis. This study presents a 157 nm F2 laser system with an optical path purged and protected by an inert gas (N2) and provides a comprehensive performance evaluation of its integration with LA-(MC-) ICP-MS. The 157 nm laser effectively ablates transparent minerals such as quartz and fluorite, producing flat-bottomed craters free of fracturing. Systematic evaluations of trace elements, zircon U–Pb dating, and in situ Hf–B isotopic analyses consistently demonstrate robust analytical performance of the 157 nm laser across diverse in situ microanalysis applications. These capabilities position the 157 nm laser to enhance spatial resolution in highly transparent minerals, facilitating the acquisition of finer-scale chemical insights for a broad range of Earth science and environmental investigations.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-08-17
DOI
https://doi.org/10.1021/acs.analchem.6c03922
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial PerformanceEvaluation of an Ultraviolet 157nm Laser Ablation System for ICP–MS Analysis

Zhian Bao, Kaiyun Chen, Honglin Yuan, Deyi Peng
Analytical Chemistry
Analytical chemistry methods development
article

Initial PerformanceEvaluation of an Ultraviolet 157nm Laser Ablation System for ICP–MS Analysis

Zhian Bao, Kaiyun Chen, Honglin Yuan, Deyi Peng
article en

Abstract

Abstract Laser wavelength largely governs analytical accuracy in laser ablation microanalysis. Most routine laser ablation systems rely on 193 nm excimer lasers, while the considerably shorter 157 nm wavelength has only been applied sparingly to in situ microanalysis. This study presents a 157 nm F2 laser system with an optical path purged and protected by an inert gas (N2) and provides a comprehensive performance evaluation of its integration with LA-(MC-) ICP-MS. The 157 nm laser effectively ablates transparent minerals such as quartz and fluorite, producing flat-bottomed craters free of fracturing. Systematic evaluations of trace elements, zircon U–Pb dating, and in situ Hf–B isotopic analyses consistently demonstrate robust analytical performance of the 157 nm laser across diverse in situ microanalysis applications. These capabilities position the 157 nm laser to enhance spatial resolution in highly transparent minerals, facilitating the acquisition of finer-scale chemical insights for a broad range of Earth science and environmental investigations.

Analytical Chemistry
Northwest University (US)
National Natural Science Foundation of China, Northwest University, National Science and Technology Major Project
Life in Land
Openalex Percentile: Top 14%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.