Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients – insights from a randomized clinical trial

Abstract Background Mechanical power (MP) quantifies the energy transferred from the ventilator to the respiratory system and is increasingly linked to outcomes in invasively ventilated critically ill patients. Limiting MP may support lung-protective ventilation by integrating key determinants of ventilator-induced lung injury. While geometric MP, derived from pressure–volume loops, is considered the reference standard, it is not readily available at the bedside. Therefore, simplified equations are commonly used, although their agreement remains uncertain. This study evaluates the agreement of previously proposed equations to estimate inspiratory MP compared with a geometric reference. Results 494 paired values of geometric and estimated MP were collected, in 38 passively ventilated patients during closed-loop ventilation and during conventional ventilation. The median geometric MP was 17.0 [12.3–21.5] J/min. Correlation between geometric and estimated MP ranged from strong to very strong. Agreement between geometric and estimated MP was good, though bias and limits of agreement varied across the different equations. ROC analysis showed excellent discrimination for most equations across all tested cutoffs, with discrimination gradually declining at higher MP levels. Conclusion In passively ventilated critically ill patients, estimated MP showed strong to very strong correlations with the geometric reference. ROC analysis confirmed excellent discrimination, but Bland–Altman analysis revealed considerable variability, suggesting potential limitations in using these equations interchangeably in clinical or research settings. Study registration INTELLiPOWER was registered at clinicaltrials.gov (study identifier NCT04827927).

Authors

Publication Details

Journal
Intensive Care Medicine Experimental
Published
2026-08-18
DOI
https://doi.org/10.1186/s40635-026-00956-8
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients – insights from a randomized clinical trial

Simon Corrado Serafini, Eva-Maria Kleinert, Patricia van Velzen, Amanda Berg et al.
Intensive Care Medicine Experimental
Respiratory Support and Mechanisms
article

Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients – insights from a randomized clinical trial

Simon Corrado Serafini, Eva-Maria Kleinert, Patricia van Velzen, Amanda Berg, Robin L. Goossen, Michela Botta, Kim-Jana Fehlbier, Guido Mazzinari, Pim L. J. van der Heiden, Jante S. Sinnige, Laura A. Buiteman‐Kruizinga, Stephanie S. List, Ben H. de Boer, R. Appel, Tobias D. van Leijsen, Pedro Wendel Garcia, Edda Tschernko, Marcus J. Schultz, Danique Boezaart, José A. Boots, Anissa M. Tsonas, Yvonne Schriel van den Berg, Anastasia A. Guseva, Marieke Luttmer–Laven, Lotte Remmerswaal, Jan Willem H. J. Geerts, Philipp Bühler, Stephan von Düring, Bibi Bosman, Ary Serpa Neto, Coby Hoekstra–Kapitein, Philippe Bühler, Hans Last, for the INTELLiPOWER collaborative investigators, Marjolein C.W.M. Bierlee, Tom Vermeulen, Frederique Paulus
article en

Abstract

Abstract Background Mechanical power (MP) quantifies the energy transferred from the ventilator to the respiratory system and is increasingly linked to outcomes in invasively ventilated critically ill patients. Limiting MP may support lung-protective ventilation by integrating key determinants of ventilator-induced lung injury. While geometric MP, derived from pressure–volume loops, is considered the reference standard, it is not readily available at the bedside. Therefore, simplified equations are commonly used, although their agreement remains uncertain. This study evaluates the agreement of previously proposed equations to estimate inspiratory MP compared with a geometric reference. Results 494 paired values of geometric and estimated MP were collected, in 38 passively ventilated patients during closed-loop ventilation and during conventional ventilation. The median geometric MP was 17.0 [12.3–21.5] J/min. Correlation between geometric and estimated MP ranged from strong to very strong. Agreement between geometric and estimated MP was good, though bias and limits of agreement varied across the different equations. ROC analysis showed excellent discrimination for most equations across all tested cutoffs, with discrimination gradually declining at higher MP levels. Conclusion In passively ventilated critically ill patients, estimated MP showed strong to very strong correlations with the geometric reference. ROC analysis confirmed excellent discrimination, but Bland–Altman analysis revealed considerable variability, suggesting potential limitations in using these equations interchangeably in clinical or research settings. Study registration INTELLiPOWER was registered at clinicaltrials.gov (study identifier NCT04827927).

Intensive Care Medicine ExperimentalVol. 14(1)
Peace, Justice and strong institutions
Openalex Percentile: Top 10%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.