μPADs for a Safer Night’s Sleep: An Alternativefor Quality Control of Melatonin Pharmaceutical Formulations

Abstract Melatonin, known as the “sleep hormone,” has its primary function in regulating the circadian cycle, a 24 h sleep–wake pattern that leads to significant physical, mental, and behavioral changes. The use of melatonin in pharmaceutical formulations gained popularity as a tool to combat sleep disorders such as insomnia and has been increasing in the last few decades. Melatonin-based pharmaceutical formulations are classified as dietary supplements, which leads to a different perspective on the necessity of strict quality control for these products. There are already extensive descriptions in the literature of the serious side effects associated with the administration of those formulations, including, for example, higher dosages than indicated on the label or contamination by other hormones. Still, there is a gap in devices that could make an easy and low-cost determination of melatonin. This work presents a paper-based sensor for the quality control of melatonin in pharmaceutical formulations, utilizing the modified Van Urk reaction. This reaction causes a color change from white to blue on the paper surface, correlating with the melatonin concentration. The constructed sensor performed well in quantifying melatonin in solid (0.22 mg/tablet) and liquid (0.20 mg/drop) pharmaceutical formulations, considering the maximum standard deviation when compared with results obtained by a gold-standard technique (liquid chromatography). The developed method demonstrated good linearity (R2 = 0.9915) over a melatonin concentration range of 40–300 mg L–1 and exhibited a specific response to the hormone when tested against the vehicles and excipients of the pharmaceutical formulations. Therefore, the proposed sensor demonstrates excellent potential as an inexpensive tool for quality control, introducing an innovative approach to the use of paper-based microfluidic devices in this field.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-08-14
DOI
https://doi.org/10.1021/acsomega.6c03837
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

μPADs for a Safer Night’s Sleep: An Alternativefor Quality Control of Melatonin Pharmaceutical Formulations

Eduardo Luiz Rossini, Manoel Lima, Emanuel Carrilho, Laís Canniatti Brazaca et al.
ACS Omega
Biosensors and Analytical Detection
article

μPADs for a Safer Night’s Sleep: An Alternativefor Quality Control of Melatonin Pharmaceutical Formulations

Eduardo Luiz Rossini, Manoel Lima, Emanuel Carrilho, Laís Canniatti Brazaca, Ana Julia Aparecida Ramos
article en

Abstract

Abstract Melatonin, known as the “sleep hormone,” has its primary function in regulating the circadian cycle, a 24 h sleep–wake pattern that leads to significant physical, mental, and behavioral changes. The use of melatonin in pharmaceutical formulations gained popularity as a tool to combat sleep disorders such as insomnia and has been increasing in the last few decades. Melatonin-based pharmaceutical formulations are classified as dietary supplements, which leads to a different perspective on the necessity of strict quality control for these products. There are already extensive descriptions in the literature of the serious side effects associated with the administration of those formulations, including, for example, higher dosages than indicated on the label or contamination by other hormones. Still, there is a gap in devices that could make an easy and low-cost determination of melatonin. This work presents a paper-based sensor for the quality control of melatonin in pharmaceutical formulations, utilizing the modified Van Urk reaction. This reaction causes a color change from white to blue on the paper surface, correlating with the melatonin concentration. The constructed sensor performed well in quantifying melatonin in solid (0.22 mg/tablet) and liquid (0.20 mg/drop) pharmaceutical formulations, considering the maximum standard deviation when compared with results obtained by a gold-standard technique (liquid chromatography). The developed method demonstrated good linearity (R2 = 0.9915) over a melatonin concentration range of 40–300 mg L–1 and exhibited a specific response to the hormone when tested against the vehicles and excipients of the pharmaceutical formulations. Therefore, the proposed sensor demonstrates excellent potential as an inexpensive tool for quality control, introducing an innovative approach to the use of paper-based microfluidic devices in this field.

ACS Omega
Consejo Nacional de Ciencia y Tecnología (GT), Universidade de São Paulo (BR), Universidade Brasil (BR), Universidade São Francisco (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Good health and well-being
Openalex Percentile: Top 18%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.