Comparison of ESIand APPI for the Detection of NitroExplosives Using Differential Mobility Mass Spectrometry

Abstract Rapid and reliable detection of explosive residues is critical for security applications (e.g., counterterrorism) and environmental health contexts (e.g., legacy military site contamination). Key target analytes among nitro-organic explosives encompass 2,4,6-trinitrotoluene (TNT), hexogen (RDX), pentaerythritol tetranitrate (PETN) as well as 2,4-dinitrotoluene (DNT, a common military-grade TNT impurity) and 2-amino-4,6-dinitroluene (2A-DNT, a microbial degradation product of TNT). Ion mobility spectrometry is one of the key technologies for fast and reliable detection of explosives. When coupled with mass spectrometry (MS), it enables high sensitivity and precise analyte identification. In this study, a differential mobility analyzer (DMA) coupled to a triple quadrupole MS was utilized to compare two relatively orthogonal ionization techniques─atmospheric pressure photoionization (APPI) and electrospray ionization (ESI)─for explosive trace detection in calibration standards and soil extracts, applied via liquid injection or via thermal desorption from filters. Both ionization techniques showed good linearity and enabled sensitive detection of the tested explosives. While APPI showed increased sensitivity toward dinitrotoluenes (DNT, 2A-DNT), ESI performed significantly better for TNT, RDX, and PETN but failed to detect DNT via thermal desorption. Both ionization techniques were further applied to the analysis of explosives in soil extracts, providing meaningful insights into their applicability for field sample analysis and revealing distinct effects of matrix components on ion source behavior and detection performance. The study underscores the practical relevance of the approach while offering a balanced evaluation of the methodological strengths and limitations.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-08-14
DOI
https://doi.org/10.1021/acsomega.6c06952
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of ESIand APPI for the Detection of NitroExplosives Using Differential Mobility Mass Spectrometry

K. Konstantynovski, René Breuch, Vanessa Lünsmann, Silvia A. M. Herrmann
ACS Omega
Mass Spectrometry Techniques and Applications
article

Comparison of ESIand APPI for the Detection of NitroExplosives Using Differential Mobility Mass Spectrometry

K. Konstantynovski, René Breuch, Vanessa Lünsmann, Silvia A. M. Herrmann
article en

Abstract

Abstract Rapid and reliable detection of explosive residues is critical for security applications (e.g., counterterrorism) and environmental health contexts (e.g., legacy military site contamination). Key target analytes among nitro-organic explosives encompass 2,4,6-trinitrotoluene (TNT), hexogen (RDX), pentaerythritol tetranitrate (PETN) as well as 2,4-dinitrotoluene (DNT, a common military-grade TNT impurity) and 2-amino-4,6-dinitroluene (2A-DNT, a microbial degradation product of TNT). Ion mobility spectrometry is one of the key technologies for fast and reliable detection of explosives. When coupled with mass spectrometry (MS), it enables high sensitivity and precise analyte identification. In this study, a differential mobility analyzer (DMA) coupled to a triple quadrupole MS was utilized to compare two relatively orthogonal ionization techniques─atmospheric pressure photoionization (APPI) and electrospray ionization (ESI)─for explosive trace detection in calibration standards and soil extracts, applied via liquid injection or via thermal desorption from filters. Both ionization techniques showed good linearity and enabled sensitive detection of the tested explosives. While APPI showed increased sensitivity toward dinitrotoluenes (DNT, 2A-DNT), ESI performed significantly better for TNT, RDX, and PETN but failed to detect DNT via thermal desorption. Both ionization techniques were further applied to the analysis of explosives in soil extracts, providing meaningful insights into their applicability for field sample analysis and revealing distinct effects of matrix components on ion source behavior and detection performance. The study underscores the practical relevance of the approach while offering a balanced evaluation of the methodological strengths and limitations.

ACS Omega
Hochschule Bonn-Rhein-Sieg (DE), Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
Life in Land
Openalex Percentile: Top 18%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.