High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier

OBJECTIVE: Continuous resistive layer position-sensitive silicon photomultiplier (CRL PS-SiPM) is a class of position-sensitive SiPMs developed for the readout of fine-pitch scintillator crystal arrays. This study aimed to evaluate the performance of dual-ended readout positron emission tomography (PET) detectors based on CRL PS-SiPMs and 0.5 mm pitch LYSO arrays. APPROACH: A dual-ended readout detector was constructed by coupling two CRL PS-SiPMs to both ends of a 10 × 10 array of polished LYSO elements, each measuring 0.44 × 0.44 × 20 mm³. Each CRL PS-SiPM had an active area of 6.24 × 6.24 mm² and was fabricated using 20 µm microcells. Detector performance, including flood histogram quality, energy resolution, and coincidence timing resolution, was characterized at bias voltages ranging from 30.0 to 33.0 V in 0.5 V increments, and at 3 °C, 14 °C, and 24 °C. Depth-of-interaction (DOI) resolution was evaluated at the optimal bias voltage determined from the flood histogram and at all three temperatures. MAIN RESULTS: Temperature had a negligible effect on detector performance, indicating that CRL PS-SiPMs are practical photodetector candidates for high spatial resolution PET scanners. All LYSO crystals were clearly resolved in the flood histograms. At 24 °C and a bias voltage of 32.5 V, which provided the best flood histogram, the average energy resolution, coincidence timing resolution, and DOI resolution across all crystals were 22.7 ± 3.4%, 1152 ± 43 ps, and 1.78 ± 0.20 mm, respectively. SIGNIFICANCE: These results demonstrate that CRL PS-SiPMs are promising photodetectors for high spatial resolution PET applications, particularly for systems requiring detectors with sub-millimeter pitch scintillator crystal arrays and DOI capability.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-08-14
DOI
https://doi.org/10.1088/1361-6560/ae9a28
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier

Junwei Du, H.B. Wang, Jiahao Xie
Physics in Medicine and Biology
Radiation Detection and Scintillator Technologies
article

High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier

Junwei Du, H.B. Wang, Jiahao Xie
article en

Abstract

OBJECTIVE: Continuous resistive layer position-sensitive silicon photomultiplier (CRL PS-SiPM) is a class of position-sensitive SiPMs developed for the readout of fine-pitch scintillator crystal arrays. This study aimed to evaluate the performance of dual-ended readout positron emission tomography (PET) detectors based on CRL PS-SiPMs and 0.5 mm pitch LYSO arrays. APPROACH: A dual-ended readout detector was constructed by coupling two CRL PS-SiPMs to both ends of a 10 × 10 array of polished LYSO elements, each measuring 0.44 × 0.44 × 20 mm³. Each CRL PS-SiPM had an active area of 6.24 × 6.24 mm² and was fabricated using 20 µm microcells. Detector performance, including flood histogram quality, energy resolution, and coincidence timing resolution, was characterized at bias voltages ranging from 30.0 to 33.0 V in 0.5 V increments, and at 3 °C, 14 °C, and 24 °C. Depth-of-interaction (DOI) resolution was evaluated at the optimal bias voltage determined from the flood histogram and at all three temperatures. MAIN RESULTS: Temperature had a negligible effect on detector performance, indicating that CRL PS-SiPMs are practical photodetector candidates for high spatial resolution PET scanners. All LYSO crystals were clearly resolved in the flood histograms. At 24 °C and a bias voltage of 32.5 V, which provided the best flood histogram, the average energy resolution, coincidence timing resolution, and DOI resolution across all crystals were 22.7 ± 3.4%, 1152 ± 43 ps, and 1.78 ± 0.20 mm, respectively. SIGNIFICANCE: These results demonstrate that CRL PS-SiPMs are promising photodetectors for high spatial resolution PET applications, particularly for systems requiring detectors with sub-millimeter pitch scintillator crystal arrays and DOI capability.

Physics in Medicine and Biology
University of California, Davis (US)
National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 10%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.