Human factors testing in a novel automated peritoneal dialysis system

Background Because automated peritoneal dialysis (APD) systems are used in the home and operated by patients or their care partners, the human–device interface must be thoughtfully designed to facilitate intuitive operation to reduce the risk of errors that could occur during their use. User-friendly design should also help reduce anxiety to peritoneal dialysis (PD) adoption by patients incident to end-stage kidney disease (ESKD). Usability issues remain a significant barrier to PD adoption and are an important contributor to premature death, serious injuries, and PD technique failure. Methods A summative human factors usability study was conducted on a novel, gravity-based APD device ( Archimedes ™) with 15 current or former PD patients and 15 dialysis nurses. Participants were trained for 2 h, followed by a training decay period, then evaluated with critical Use Scenario tasks consisting of Simulated Use tasks and Knowledge tasks reflecting tasks that could result in patient harm if performed incorrectly. Results Of the Simulated Use tasks evaluated, 97.3% were deemed successful across all users. This high success rate demonstrates the effectiveness of the Archimedes APD device in facilitating the tasks required for PD. For patients, success outcomes were achieved in 96.8% of Simulated Use tasks. Nurses achieved a success rate of 97.8% for Simulated Use tasks evaluated. For Knowledge tasks, success outcomes were achieved in 99.3% and 98.6% of tasks for patients and nurses. Conclusion In this summative human factors usability study, the Archimedes APD system usability was found to be safe, accessible and easy for its intended users and use environments after the relatively short training period compared to the status quo.

Authors

Institutions

Publication Details

Journal
Peritoneal Dialysis International
Published
2026-08-14
DOI
https://doi.org/10.1177/08968608261476545
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Human factors testing in a novel automated peritoneal dialysis system

Vikram Aggarwal, Nupur Gupta, Steve J. Lindo, Rick Pendergraft et al.
Peritoneal Dialysis International
Dialysis and Renal Disease Management
article

Human factors testing in a novel automated peritoneal dialysis system

Vikram Aggarwal, Nupur Gupta, Steve J. Lindo, Rick Pendergraft, James A. Sloand, Brent Miller
article en

Abstract

Background Because automated peritoneal dialysis (APD) systems are used in the home and operated by patients or their care partners, the human–device interface must be thoughtfully designed to facilitate intuitive operation to reduce the risk of errors that could occur during their use. User-friendly design should also help reduce anxiety to peritoneal dialysis (PD) adoption by patients incident to end-stage kidney disease (ESKD). Usability issues remain a significant barrier to PD adoption and are an important contributor to premature death, serious injuries, and PD technique failure. Methods A summative human factors usability study was conducted on a novel, gravity-based APD device ( Archimedes ™) with 15 current or former PD patients and 15 dialysis nurses. Participants were trained for 2 h, followed by a training decay period, then evaluated with critical Use Scenario tasks consisting of Simulated Use tasks and Knowledge tasks reflecting tasks that could result in patient harm if performed incorrectly. Results Of the Simulated Use tasks evaluated, 97.3% were deemed successful across all users. This high success rate demonstrates the effectiveness of the Archimedes APD device in facilitating the tasks required for PD. For patients, success outcomes were achieved in 96.8% of Simulated Use tasks. Nurses achieved a success rate of 97.8% for Simulated Use tasks evaluated. For Knowledge tasks, success outcomes were achieved in 99.3% and 98.6% of tasks for patients and nurses. Conclusion In this summative human factors usability study, the Archimedes APD system usability was found to be safe, accessible and easy for its intended users and use environments after the relatively short training period compared to the status quo.

Peritoneal Dialysis International
George Washington University (US), Oklahoma City University (US), University School (US), Indiana University School of Medicine, Indiana University (US)
Quality Education
Openalex Percentile: Top 9%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.