Deep learning model for automatic detection of incidental adrenal abnormalities on low-dose computed tomography images

Abstract Background To investigate the feasibility of employing deep learning models for automated segmentation and classification of adrenal incidental abnormalities on low-dose CT images. Methods Four distinct CT cohorts were retrospectively collected for deep learning models development (cohort A, n = 2574; cohort B, n = 1205), internal evaluation (cohort C, n = 3681), and external evaluation (cohort D, n = 779). Two experienced uroradiologists independently reviewed the CT images and labeled the adrenal glands as normal or abnormal based on predefined criteria encompassing both density and morphological abnormalities, with any discrepancies resolved through consultation. The model development cohorts were divided into a training set, a validation set, and a test set. Deep learning models for segmentation and classification were trained and evaluated on internal and external sets, with the dice similarity coefficient (DSC), area under precision–recall curves (AUPRC), and area under receiver operating characteristic curves (AUROC) as evaluation metrics. Adrenal descriptions from radiology reports were extracted to compare with the model’s performance. Results For adrenal gland segmentation, the DSC values for the test set, internal validation cohort, and external validation cohort were 0.839 (IQR: 0.783–0.871), 0.870 (IQR: 0.819–0.902), and 0.799 (IQR: 0.729–0.849), respectively. For adrenal gland classification, the AI model achieved AUPRC values of 0.913, 0.753, and 0.927 in the test set, internal validation cohort, and external validation cohort, respectively, outperforming routine radiology reporting (AUPRC: 0.809, 0.708, 0.591; all P < 0.05). Corresponding AUROC values were 0.956, 0.942, and 0.977 for the AI model, which also outperformed routine radiology reporting (AUROC: 0.889, 0.705, 0.551; all P < 0.05). Conclusions The deep learning models showed promise in automated adrenal segmentation and classification, highlighting AI’s potential to improve detection of adrenal abnormalities in LDCT scans. Trial registration This study has been registered on ClinicalTrials.gov on August 25, 2025, with the unique identifier NCT07198152.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-08-14
DOI
https://doi.org/10.1186/s12880-026-02651-2
Primary Topic
Adrenal and Paraganglionic Tumors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning model for automatic detection of incidental adrenal abnormalities on low-dose computed tomography images

Zheng Zhang, Chongchen Ma, Wenzhi Gao, Xiangpeng Wang et al.
BMC Medical Imaging
Adrenal and Paraganglionic Tumors
article

Deep learning model for automatic detection of incidental adrenal abnormalities on low-dose computed tomography images

Zheng Zhang, Chongchen Ma, Wenzhi Gao, Xiangpeng Wang, Shiwei Chen, He Wang, Guangyong Shi, Tong Liu, Wencong Han, Kexin Wang, Jiangtao Liu
article en

Abstract

Abstract Background To investigate the feasibility of employing deep learning models for automated segmentation and classification of adrenal incidental abnormalities on low-dose CT images. Methods Four distinct CT cohorts were retrospectively collected for deep learning models development (cohort A, n = 2574; cohort B, n = 1205), internal evaluation (cohort C, n = 3681), and external evaluation (cohort D, n = 779). Two experienced uroradiologists independently reviewed the CT images and labeled the adrenal glands as normal or abnormal based on predefined criteria encompassing both density and morphological abnormalities, with any discrepancies resolved through consultation. The model development cohorts were divided into a training set, a validation set, and a test set. Deep learning models for segmentation and classification were trained and evaluated on internal and external sets, with the dice similarity coefficient (DSC), area under precision–recall curves (AUPRC), and area under receiver operating characteristic curves (AUROC) as evaluation metrics. Adrenal descriptions from radiology reports were extracted to compare with the model’s performance. Results For adrenal gland segmentation, the DSC values for the test set, internal validation cohort, and external validation cohort were 0.839 (IQR: 0.783–0.871), 0.870 (IQR: 0.819–0.902), and 0.799 (IQR: 0.729–0.849), respectively. For adrenal gland classification, the AI model achieved AUPRC values of 0.913, 0.753, and 0.927 in the test set, internal validation cohort, and external validation cohort, respectively, outperforming routine radiology reporting (AUPRC: 0.809, 0.708, 0.591; all P < 0.05). Corresponding AUROC values were 0.956, 0.942, and 0.977 for the AI model, which also outperformed routine radiology reporting (AUROC: 0.889, 0.705, 0.551; all P < 0.05). Conclusions The deep learning models showed promise in automated adrenal segmentation and classification, highlighting AI’s potential to improve detection of adrenal abnormalities in LDCT scans. Trial registration This study has been registered on ClinicalTrials.gov on August 25, 2025, with the unique identifier NCT07198152.

BMC Medical Imaging
Peking University (CN), BOE Technology Group (China) (CN), Peking University First Hospital (CN)
Openalex Percentile: Top 7%
Adrenal and Paraganglionic Tumors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.