Load to Failure for a Novel Scapholunate Bridge Augmentation Technique

Abstract We sought to establish load to failure for a novel Bridge Augmentation technique using all-suture, knotless anchors to treat scapholunate interosseous ligament (SLIL) injury. Secondarily, we determined whether there exists any correlation between load to failure and either age or body mass index (BMI), and reported measurements based on sex. We performed a cadaveric biomechanical study to evaluate our technique. Seven cadaveric specimens with no prior carpal instability/degeneration were included. After sectioning of the SLIL, the bridge augmentation was performed by placing one anchor in the scaphoid and one in the lunate, then affixing them to one another to bridge the scapholunate interval. Load to failure was assessed for each specimen, and mean load to failure was 91.8 N (standard deviation [SD] 25.1). A weak negative correlation was found between age and load to failure (r = − 0.36), and a weak positive correlation between BMI and load to failure (r = 0.37). Mean load to failure in female specimens was 97.8 N (SD 11.5) and in male specimens was 83.7 N (SD 34.4). Our results for load to failure for the bridge augmentation technique provide similar or superior results compared with many SLIL repair methods. Several existing repair techniques have load to failure ranging from 30 N to 91 N. Some techniques with extensive reconstruction or bulky extra-articular augmentation report higher load to failure but come with downsides of multiple bony tunnels and/or potential irritation of the radiocarpal articulation. We present a biomechanically robust technique of bridge augmentation to treat SLIL injury using all-suture, knotless anchors. This novel method allows for minimal bone loss during placement, no bulky, extra-articular construct, and no risk of a hard body in the joint in the event of anchor pull-out.

Authors

Institutions

Publication Details

Journal
Journal of Wrist Surgery
Published
2026-08-14
DOI
https://doi.org/10.1055/a-2920-2614
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Load to Failure for a Novel Scapholunate Bridge Augmentation Technique

Kathleen N. Meyers, Rafa Rahman, Michael Mazzucco, Raylin Xu et al.
Journal of Wrist Surgery
Orthopedic Surgery and Rehabilitation
article

Load to Failure for a Novel Scapholunate Bridge Augmentation Technique

Kathleen N. Meyers, Rafa Rahman, Michael Mazzucco, Raylin Xu, Michelle G. Carlson
article en

Abstract

Abstract We sought to establish load to failure for a novel Bridge Augmentation technique using all-suture, knotless anchors to treat scapholunate interosseous ligament (SLIL) injury. Secondarily, we determined whether there exists any correlation between load to failure and either age or body mass index (BMI), and reported measurements based on sex. We performed a cadaveric biomechanical study to evaluate our technique. Seven cadaveric specimens with no prior carpal instability/degeneration were included. After sectioning of the SLIL, the bridge augmentation was performed by placing one anchor in the scaphoid and one in the lunate, then affixing them to one another to bridge the scapholunate interval. Load to failure was assessed for each specimen, and mean load to failure was 91.8 N (standard deviation [SD] 25.1). A weak negative correlation was found between age and load to failure (r = − 0.36), and a weak positive correlation between BMI and load to failure (r = 0.37). Mean load to failure in female specimens was 97.8 N (SD 11.5) and in male specimens was 83.7 N (SD 34.4). Our results for load to failure for the bridge augmentation technique provide similar or superior results compared with many SLIL repair methods. Several existing repair techniques have load to failure ranging from 30 N to 91 N. Some techniques with extensive reconstruction or bulky extra-articular augmentation report higher load to failure but come with downsides of multiple bony tunnels and/or potential irritation of the radiocarpal articulation. We present a biomechanically robust technique of bridge augmentation to treat SLIL injury using all-suture, knotless anchors. This novel method allows for minimal bone loss during placement, no bulky, extra-articular construct, and no risk of a hard body in the joint in the event of anchor pull-out.

Journal of Wrist Surgery
Hospital for Special Surgery (US), Cornell University (US), Tri-Institutional PhD Program in Chemical Biology (US)
Hospital for Special Surgery
Openalex Percentile: Top 7%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.