Noise‐Level Adaptive Diffusion Priors for Zero‐Shot Low‐Field MRI Quality Enhancement

Low-field MRI (LF-MRI) improves imaging accessibility, but its practical utility is often limited by reduced signal-to-noise ratio, weaker tissue contrast, and variable image quality. These challenges are further compounded by the limited availability of low-field training data across scanners and the fact that raw k-space data are not always accessible in research and clinical workflows. In this study, we adapted a high-field-trained diffusion model for LF-MRI quality enhancement without low-field retraining or fine-tuning. During inference, the pretrained diffusion prior was combined with noise-level adaptive measurement guidance to suppress low-field noise while maintaining consistency with measurement-supported anatomical structures. With phase augmentation, this framework was further extended to magnitude-only DICOM-exported inputs when measured phase information was unavailable. The method was evaluated on 10 locally recruited healthy volunteers scanned at 0.05, 0.3, and 3 T, a public 0.064-T healthy-subject dataset with 10 paired cases, and patient cases acquired at 0.05 and 0.35 T. Compared with raw LF input and representative baselines including BM3D, MiDiffusion, and NAFNet, the proposed method (Nila) improved visual image quality, noise suppression, and tissue contrast, while preserving lesion-region appearance in patient cases. On the 0.3 and 0.064 T datasets with coregistered 3-T references, Nila achieved the best LPIPS and the highest or tied-highest NMI across contrasts, indicating improved similarity to the high-field reference. Multisample posterior inference further produced uncertainty maps that provide an explainable-AI view of spatial output variability, with elevated variance mainly localized to tissue boundaries and ambiguous regions. These results suggest that high-field diffusion priors can serve as practical and reusable tools for LF-MRI enhancement across heterogeneous systems.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-08-14
DOI
https://doi.org/10.1002/nbm.70373
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise‐Level Adaptive Diffusion Priors for Zero‐Shot Low‐Field MRI Quality Enhancement

Mengye Lyu, Shoujin Huang, 蔡家财, EX Wu et al.
NMR in Biomedicine
MRI in cancer diagnosis
article

Noise‐Level Adaptive Diffusion Priors for Zero‐Shot Low‐Field MRI Quality Enhancement

Mengye Lyu, Shoujin Huang, 蔡家财, EX Wu, Huaishui Yang, Xiao Lingfang, Zhuangzhuang Miao, Zihao Wang, Shaojun Liu, Yilong Liu, Min Wang, Jiangbin Zhang
article en

Abstract

Low-field MRI (LF-MRI) improves imaging accessibility, but its practical utility is often limited by reduced signal-to-noise ratio, weaker tissue contrast, and variable image quality. These challenges are further compounded by the limited availability of low-field training data across scanners and the fact that raw k-space data are not always accessible in research and clinical workflows. In this study, we adapted a high-field-trained diffusion model for LF-MRI quality enhancement without low-field retraining or fine-tuning. During inference, the pretrained diffusion prior was combined with noise-level adaptive measurement guidance to suppress low-field noise while maintaining consistency with measurement-supported anatomical structures. With phase augmentation, this framework was further extended to magnitude-only DICOM-exported inputs when measured phase information was unavailable. The method was evaluated on 10 locally recruited healthy volunteers scanned at 0.05, 0.3, and 3 T, a public 0.064-T healthy-subject dataset with 10 paired cases, and patient cases acquired at 0.05 and 0.35 T. Compared with raw LF input and representative baselines including BM3D, MiDiffusion, and NAFNet, the proposed method (Nila) improved visual image quality, noise suppression, and tissue contrast, while preserving lesion-region appearance in patient cases. On the 0.3 and 0.064 T datasets with coregistered 3-T references, Nila achieved the best LPIPS and the highest or tied-highest NMI across contrasts, indicating improved similarity to the high-field reference. Multisample posterior inference further produced uncertainty maps that provide an explainable-AI view of spatial output variability, with elevated variance mainly localized to tissue boundaries and ambiguous regions. These results suggest that high-field diffusion priors can serve as practical and reusable tools for LF-MRI enhancement across heterogeneous systems.

NMR in BiomedicineVol. 39(9)
Jinan University (CN), Shanghai Huayi Group (China) (CN), Hongzhiwei Technology (China) (CN), Shenzhen Technology University (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN), Zhejiang University (CN), University of Hong Kong (HK)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 10%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.