PCDA–EDA Colorimetric Nanofiber Sensor for Rapid Visual GHB Screening: Linker Reassignment and Scalable Fabrication

γ-Hydroxybutyric acid (GHB), a colorless and odorless central nervous system depressant associated with drug-facilitated sexual assault, demands rapid on-site detection. Polydiacetylene (PDA) colorimetric sensors derived from 10,12-pentacosadiynoic acid (PCDA) conjugates are a promising platform, but the molecular origin of GHB recognition in PCDA–gabazine systems has remained unresolved. Here, we compare a series of structurally related PCDA conjugates to examine how the chemical state of the EDA-derived unit affects the GHB-induced colorimetric response. A side-by-side substituent screen of three PCDA derivatives showed that PCDA–EDA produced the largest colorimetric response (ΔR = 53) within 30 s, the hydrazide analogue gave a moderate response (ΔR = 34), and a simple amide was negligible (ΔR = 12). By contrast, a PCDA–gabazine mat prepared by the same protocol showed only a subtle, barely discernible color shift after several hours and remained predominantly blue even after approximately 24 h, without a visually appreciable blue-to-red transition. This difference suggests that the accessible free primary amine of PCDA–EDA is an important factor contributing to its faster and stronger response. Building on this mechanistic finding, we replaced the previously used PVDF–HFP/PEO matrix with a cellulose/PVDF–HFP formulation processed from DMF and adopted multi-nozzle electrospinning, reducing the fabrication time from approximately 120 to 30 min per sheet, corresponding to a 75% reduction in processing time. The sensor mat showed a clearly distinguishable, dose-dependent visual response across 0.5–3% w/v GHB within 30 s, covering the forensically relevant concentration window. These findings reposition linker architecture as a central design parameter for PDA-based forensic colorimetric sensors.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-08-14
DOI
https://doi.org/10.3390/bios16080440
Primary Topic
Polydiacetylene-based materials and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PCDA–EDA Colorimetric Nanofiber Sensor for Rapid Visual GHB Screening: Linker Reassignment and Scalable Fabrication

Om Darlami, J.Y. Lee, Seunghye Yang, Dongyun Shin
Biosensors
Polydiacetylene-based materials and applications
article

PCDA–EDA Colorimetric Nanofiber Sensor for Rapid Visual GHB Screening: Linker Reassignment and Scalable Fabrication

Om Darlami, J.Y. Lee, Seunghye Yang, Dongyun Shin
article en

Abstract

γ-Hydroxybutyric acid (GHB), a colorless and odorless central nervous system depressant associated with drug-facilitated sexual assault, demands rapid on-site detection. Polydiacetylene (PDA) colorimetric sensors derived from 10,12-pentacosadiynoic acid (PCDA) conjugates are a promising platform, but the molecular origin of GHB recognition in PCDA–gabazine systems has remained unresolved. Here, we compare a series of structurally related PCDA conjugates to examine how the chemical state of the EDA-derived unit affects the GHB-induced colorimetric response. A side-by-side substituent screen of three PCDA derivatives showed that PCDA–EDA produced the largest colorimetric response (ΔR = 53) within 30 s, the hydrazide analogue gave a moderate response (ΔR = 34), and a simple amide was negligible (ΔR = 12). By contrast, a PCDA–gabazine mat prepared by the same protocol showed only a subtle, barely discernible color shift after several hours and remained predominantly blue even after approximately 24 h, without a visually appreciable blue-to-red transition. This difference suggests that the accessible free primary amine of PCDA–EDA is an important factor contributing to its faster and stronger response. Building on this mechanistic finding, we replaced the previously used PVDF–HFP/PEO matrix with a cellulose/PVDF–HFP formulation processed from DMF and adopted multi-nozzle electrospinning, reducing the fabrication time from approximately 120 to 30 min per sheet, corresponding to a 75% reduction in processing time. The sensor mat showed a clearly distinguishable, dose-dependent visual response across 0.5–3% w/v GHB within 30 s, covering the forensically relevant concentration window. These findings reposition linker architecture as a central design parameter for PDA-based forensic colorimetric sensors.

BiosensorsVol. 16(8)
Gachon University (KR)
Ministry of Education - Singapore, Gachon University, Ministry of Science and ICT, South Korea
Gender equality
Openalex Percentile: Top 18%
Polydiacetylene-based materials and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.