A Physics-Informed Hybrid Method for Rapid Constant-Power State-of-Power Evaluation of Lithium-Ion Batteries

In short-duration power-support applications of energy storage stations, state of power (SOP) estimation should reflect the constant-power boundary over the target horizon, while constant-current extrapolation may misrepresent the current rise caused by voltage decline. This study proposes a 30 s constant-power SOP evaluation framework for portable inspection, decoupling parameter inversion from boundary propagation. The method uses a single-particle model with electrolyte dynamics (SPMe) with degradation factors for ohmic resistance, kinetics, and diffusion. The ohmic degradation factor is determined through time-zero voltage-drop hard calibration, while the kinetic and diffusion degradation factors are identified from 30 s constant-current pulse responses using physics-informed neural network (PINN)-based inversion, and the constant-power boundary is solved by Runge–Kutta integration and bisection search. In model-consistent closed-loop verification, which assesses numerical and inversion consistency under matched-model assumptions rather than independent physical accuracy, the method achieved a mean absolute error (MAE) of 0.100%, a 95th-percentile error of 0.503%, and a maximum error of 2.019%, below the constant-current approximation and first-order equivalent circuit model baselines within the matched-model synthetic setting. Its Jetson Nano-equivalent runtime was approximately 0.630 s. An external proxy comparison using 154 discharge pulses from a public HPPC dataset for an LCO-graphite cell showed an MAE of 0.41 W relative to the pulse-power proxy. This result measures agreement with the selected pulse-power proxy rather than accuracy against a strictly defined 30 s constant-power ground truth. The 10 mV-noise case increased the SOP MAE to 3.868%, indicating substantial sensitivity to voltage-measurement disturbance and the need for validated signal conditioning. These results indicate a physically interpretable and computationally feasible candidate framework for rapid battery power screening, while direct constant-power experiments, broader chemistry coverage, and measured-noise validation remain necessary before field deployment.

Authors

Institutions

Publication Details

Journal
Inventions
Published
2026-08-14
DOI
https://doi.org/10.3390/inventions11040084
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Physics-Informed Hybrid Method for Rapid Constant-Power State-of-Power Evaluation of Lithium-Ion Batteries

Jiewen Wang, Zhengxiang Song, Peihao Yang, Ziyao Wang
Inventions
Advanced Battery Technologies Research
article

A Physics-Informed Hybrid Method for Rapid Constant-Power State-of-Power Evaluation of Lithium-Ion Batteries

Jiewen Wang, Zhengxiang Song, Peihao Yang, Ziyao Wang
article en

Abstract

In short-duration power-support applications of energy storage stations, state of power (SOP) estimation should reflect the constant-power boundary over the target horizon, while constant-current extrapolation may misrepresent the current rise caused by voltage decline. This study proposes a 30 s constant-power SOP evaluation framework for portable inspection, decoupling parameter inversion from boundary propagation. The method uses a single-particle model with electrolyte dynamics (SPMe) with degradation factors for ohmic resistance, kinetics, and diffusion. The ohmic degradation factor is determined through time-zero voltage-drop hard calibration, while the kinetic and diffusion degradation factors are identified from 30 s constant-current pulse responses using physics-informed neural network (PINN)-based inversion, and the constant-power boundary is solved by Runge–Kutta integration and bisection search. In model-consistent closed-loop verification, which assesses numerical and inversion consistency under matched-model assumptions rather than independent physical accuracy, the method achieved a mean absolute error (MAE) of 0.100%, a 95th-percentile error of 0.503%, and a maximum error of 2.019%, below the constant-current approximation and first-order equivalent circuit model baselines within the matched-model synthetic setting. Its Jetson Nano-equivalent runtime was approximately 0.630 s. An external proxy comparison using 154 discharge pulses from a public HPPC dataset for an LCO-graphite cell showed an MAE of 0.41 W relative to the pulse-power proxy. This result measures agreement with the selected pulse-power proxy rather than accuracy against a strictly defined 30 s constant-power ground truth. The 10 mV-noise case increased the SOP MAE to 3.868%, indicating substantial sensitivity to voltage-measurement disturbance and the need for validated signal conditioning. These results indicate a physically interpretable and computationally feasible candidate framework for rapid battery power screening, while direct constant-power experiments, broader chemistry coverage, and measured-noise validation remain necessary before field deployment.

InventionsVol. 11(4)
Tsinghua Sichuan Energy Internet Research Institute (CN), Thermal Power Research Institute (CN), China Coal Research Institute (China) (CN), Xi'an Jiaotong University (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 16%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.