Harmonic Mitigation in Nonlinear Load Systems Using D-STATCOM

Nonlinear loads such as adjustable speed drives, rectifiers, and power electronic converters inject significant harmonic currents into the power system, degrading power quality and causing excessive Total Harmonic Distortion (THD). This paper presents a simulation-based performance analysis of a Distribution Static Compensator (D-STATCOM) for harmonic mitigation under nonlinear load conditions. A MATLAB/Simulink model is developed to evaluate the system with and without the D-STATCOM. Without compensation, the voltage and current THD is observed to be approximately 27.21%, which is far above the limit recommended by IEEE Std. 519. With the D-STATCOM connected, the THD is reduced to approximately 7.58%, and the source current waveform becomes near-sinusoidal. The results demonstrate that the proposed D-STATCOM effectively mitigates harmonics and improves power quality, and directions for further improvement toward full standard compliance are discussed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-08-14
DOI
https://doi.org/10.5281/zenodo.21929532
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Mitigation in Nonlinear Load Systems Using D-STATCOM

Ashraf Ali, Priyank Srivastava, Lalit Jain
Zenodo (CERN European Organization for Nuclear Research)
Power Quality and Harmonics
article

Harmonic Mitigation in Nonlinear Load Systems Using D-STATCOM

Ashraf Ali, Priyank Srivastava, Lalit Jain
article en

Abstract

Nonlinear loads such as adjustable speed drives, rectifiers, and power electronic converters inject significant harmonic currents into the power system, degrading power quality and causing excessive Total Harmonic Distortion (THD). This paper presents a simulation-based performance analysis of a Distribution Static Compensator (D-STATCOM) for harmonic mitigation under nonlinear load conditions. A MATLAB/Simulink model is developed to evaluate the system with and without the D-STATCOM. Without compensation, the voltage and current THD is observed to be approximately 27.21%, which is far above the limit recommended by IEEE Std. 519. With the D-STATCOM connected, the THD is reduced to approximately 7.58%, and the source current waveform becomes near-sinusoidal. The results demonstrate that the proposed D-STATCOM effectively mitigates harmonics and improves power quality, and directions for further improvement toward full standard compliance are discussed.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 18%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.