Automated Cardiac Reorientation and Slice Extraction in Cine Coronary CT Angiography: Agreement with Cardiovascular Magnetic Resonance

Visualization of coronary computed tomography angiography (CCTA) in standard cardiac planes requires reorientation of the three-dimensional image volume because the heart is double-oblique relative to the axial scan plane. To standardize this process across multi-phase cine CCTA, we developed an automated framework that segments cardiac structures and detects anatomic landmarks to define a patient-specific cardiac coordinate system. Landmark-derived left ventricular (LV) long-axis and LV-to-right ventricular transverse vectors were used to compute a rotation matrix for reorienting all 20 cine CCTA volumes. Six fixed slice planes were then defined to extract three long-axis (LAX) and three short-axis (SAX) slices at each phase. Matched CCTA and cardiac magnetic resonance (MR) slices were compared in 25 patients at diastasis, end-diastole (ED), and end-systole (ES), using automated segmentation-derived measurements of the combined LV cavity and LV myocardium area (LV + LVM). Agreement was evaluated with intraclass correlation coefficients (ICCs), Bland–Altman analysis, and repeated-measures mixed-effects models. ICCs were 0.927 (95% CI, 0.895 to 0.950) at diastasis, 0.950 (95% CI, 0.928 to 0.966) at ED, and 0.919 (95% CI, 0.887 to 0.943) at ES. Bland–Altman analysis showed small CT-positive biases of 1.05, 0.47, and 1.86 cm2 at diastasis, ED, and ES, corresponding to relative biases of 2.8%, 1.2%, and 5.8% of the phase-specific mean MR LV + LVM area. Mixed-effects models showed no statistically significant phase-level bias at diastasis or ED, whereas ES showed a small but significant CT-positive bias. These findings support automated CCTA reorientation as an interpretable framework for reproducible LAX/SAX slice extraction and future quantitative functional cine CCTA analysis.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-08-14
DOI
https://doi.org/10.3390/tomography12080114
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Cardiac Reorientation and Slice Extraction in Cine Coronary CT Angiography: Agreement with Cardiovascular Magnetic Resonance

Matthew Jacobs, Li‐Yueh Hsu, Lin‐Ching Chang, Marcus Y. Chen et al.
Tomography
Cardiac Imaging and Diagnostics
article

Automated Cardiac Reorientation and Slice Extraction in Cine Coronary CT Angiography: Agreement with Cardiovascular Magnetic Resonance

Matthew Jacobs, Li‐Yueh Hsu, Lin‐Ching Chang, Marcus Y. Chen, A. Sun, Andrew Heller, W. Patricia Bandettini
article en

Abstract

Visualization of coronary computed tomography angiography (CCTA) in standard cardiac planes requires reorientation of the three-dimensional image volume because the heart is double-oblique relative to the axial scan plane. To standardize this process across multi-phase cine CCTA, we developed an automated framework that segments cardiac structures and detects anatomic landmarks to define a patient-specific cardiac coordinate system. Landmark-derived left ventricular (LV) long-axis and LV-to-right ventricular transverse vectors were used to compute a rotation matrix for reorienting all 20 cine CCTA volumes. Six fixed slice planes were then defined to extract three long-axis (LAX) and three short-axis (SAX) slices at each phase. Matched CCTA and cardiac magnetic resonance (MR) slices were compared in 25 patients at diastasis, end-diastole (ED), and end-systole (ES), using automated segmentation-derived measurements of the combined LV cavity and LV myocardium area (LV + LVM). Agreement was evaluated with intraclass correlation coefficients (ICCs), Bland–Altman analysis, and repeated-measures mixed-effects models. ICCs were 0.927 (95% CI, 0.895 to 0.950) at diastasis, 0.950 (95% CI, 0.928 to 0.966) at ED, and 0.919 (95% CI, 0.887 to 0.943) at ES. Bland–Altman analysis showed small CT-positive biases of 1.05, 0.47, and 1.86 cm2 at diastasis, ED, and ES, corresponding to relative biases of 2.8%, 1.2%, and 5.8% of the phase-specific mean MR LV + LVM area. Mixed-effects models showed no statistically significant phase-level bias at diastasis or ED, whereas ES showed a small but significant CT-positive bias. These findings support automated CCTA reorientation as an interpretable framework for reproducible LAX/SAX slice extraction and future quantitative functional cine CCTA analysis.

TomographyVol. 12(8)
National Institutes of Health (US), University of America (US), National Heart, Lung, and Blood Institute (US)
National Institutes of Health
Good health and well-being
Openalex Percentile: Top 10%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.