Improved Detection of Acute Coronary Occlusion Myocardial Infarction by an Artificial Intelligence Electrocardiogram Model in Swedish Emergency Departments

Objectives The Queen of Hearts (QoH) ECG artificial intelligence model has demonstrated improved sensitivity for detecting occlusion myocardial infarction (OMI) compared with STEMI criteria, but further validation is needed. We aimed to evaluate QoH's diagnostic performance in patients with chest pain at Swedish emergency departments (EDs). Methods This retrospective analysis included consecutive patients with chest pain at the ED from the ESC-TROP study (2017-2018). Patients transferred directly from the prehospital setting to the coronary care unit were not included. OMI classification was based on angiographic data and expert adjudication. QoH, conventional STEMI criteria, and the Glasgow ECG Analysis Algorithm were applied to all cases. In addition, extended STEMI criteria incorporating additional ECG leads (-V1, -V2, -V3, -aVL, -aVR, and -III) and OMI criteria for left bundle branch block (modified Sgarbossa criteria) and left ventricular hypertrophy (ST elevation V1-V3 ≥0.25 of R and S) were applied. Results Among 24,511 patients (mean age 59 ± 19 years, 52% male), 467 (1.9%) had OMI. QoH achieved higher sensitivity than STEMI criteria (52% [47 to 57] vs 23% [19 to 27]), similar specificity (99% [99 to 99] vs 98% [98 to 98]), higher positive predictive value (51% [47 to 54] vs 17% [15 to 20]), and similar negative predictive value (99% [99 to 99] vs 98 [98 to 99]). The Glasgow algorithm obtained 32% (28 to 37) sensitivity, 98% (98 to 98) specificity, 26% (23 to 30) PPV, and 99% (99 to 99) NPV, and corresponding number for the extended criteria were 41% (36 to 45), 95% (95 to 96), 14% (12 to 15), and 99% (99 to 99). Conclusion In ED patients with chest pain, QoH improved sensitivity in OMI detection compared with currently available ECG criteria, with similar specificity.

Authors

Institutions

Publication Details

Journal
Journal of the American College of Emergency Physicians Open
Published
2026-08-14
DOI
https://doi.org/10.1016/j.acepjo.2026.100473
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Detection of Acute Coronary Occlusion Myocardial Infarction by an Artificial Intelligence Electrocardiogram Model in Swedish Emergency Departments

Arash Mokhtari, Thomas Lindow, Jakob Lundager Forberg, Anders Björkelund et al.
Journal of the American College of Emergency Physicians Open
ECG Monitoring and Analysis
article

Improved Detection of Acute Coronary Occlusion Myocardial Infarction by an Artificial Intelligence Electrocardiogram Model in Swedish Emergency Departments

Arash Mokhtari, Thomas Lindow, Jakob Lundager Forberg, Anders Björkelund, Axel Nyström, Ulf Ekelund, Robert Herman, H. Pendell Meyers, Stephen W. Smith
article en

Abstract

Objectives The Queen of Hearts (QoH) ECG artificial intelligence model has demonstrated improved sensitivity for detecting occlusion myocardial infarction (OMI) compared with STEMI criteria, but further validation is needed. We aimed to evaluate QoH's diagnostic performance in patients with chest pain at Swedish emergency departments (EDs). Methods This retrospective analysis included consecutive patients with chest pain at the ED from the ESC-TROP study (2017-2018). Patients transferred directly from the prehospital setting to the coronary care unit were not included. OMI classification was based on angiographic data and expert adjudication. QoH, conventional STEMI criteria, and the Glasgow ECG Analysis Algorithm were applied to all cases. In addition, extended STEMI criteria incorporating additional ECG leads (-V1, -V2, -V3, -aVL, -aVR, and -III) and OMI criteria for left bundle branch block (modified Sgarbossa criteria) and left ventricular hypertrophy (ST elevation V1-V3 ≥0.25 of R and S) were applied. Results Among 24,511 patients (mean age 59 ± 19 years, 52% male), 467 (1.9%) had OMI. QoH achieved higher sensitivity than STEMI criteria (52% [47 to 57] vs 23% [19 to 27]), similar specificity (99% [99 to 99] vs 98% [98 to 98]), higher positive predictive value (51% [47 to 54] vs 17% [15 to 20]), and similar negative predictive value (99% [99 to 99] vs 98 [98 to 99]). The Glasgow algorithm obtained 32% (28 to 37) sensitivity, 98% (98 to 98) specificity, 26% (23 to 30) PPV, and 99% (99 to 99) NPV, and corresponding number for the extended criteria were 41% (36 to 45), 95% (95 to 96), 14% (12 to 15), and 99% (99 to 99). Conclusion In ED patients with chest pain, QoH improved sensitivity in OMI detection compared with currently available ECG criteria, with similar specificity.

Journal of the American College of Emergency Physicians OpenVol. 7(5)
Lund University (SE), Carolinas Medical Center (US), Hennepin County Medical Center (US), Onze Lieve Vrouwziekenhuis Hospital (BE), Swedish Institute for Health Economics (SE), Helsingborgs lasarett (SE), Skåne University Hospital (SE), Alstom (Sweden) (SE), Växjö Kommun (SE)
Hjärt-Lungfonden, Vetenskapsrådet, Skånes universitetssjukhus
Good health and well-being
Openalex Percentile: Top 9%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.