Optimal amyloid and tau CSF biomarkers for the detection of amyloid and tau PET positivity in a memory clinic population

Abstract Background Accurate detection of Alzheimer’s disease (AD) pathophysiological changes is crucial for research and clinical practice. While positron emission tomography (PET) imaging is an established reference standard for detecting brain amyloid and tau deposition, cerebrospinal fluid (CSF) biomarkers offer a more accessible alternative. This study aimed to identify optimal CSF biomarkers and thresholds for predicting tau and amyloid PET positivity in a memory clinic population. Methods This cross-sectional, observational study included 220 participants from a memory clinic who underwent amyloid or tau PET scans and CSF biomarker analysis using either Fujirebio INNOTEST or LUMIPULSE assays. CSF biomarker performance was assessed via receiver operating characteristic (ROC) analysis. Double-threshold approaches were implemented to address classification uncertainty. Results Ratios combining biomarkers of both amyloid and tau, such as Aβ42/pTau, consistently outperformed individual biomarkers in detecting amyloid and tau PET positivity. For amyloid PET, the Aβ42/pTau ratio achieved an AUC of 0.93 (95% CI: 0.86–0.99) with INNOTEST and an AUC of 0.89 (95% CI: 0.8–0.98) with LUMIPULSE. For tau PET, the Aβ42/pTau ratio achieved an AUC of 0.85 (95% CI: 0.77–0.93) with INNOTEST and an AUC of 0.97 (95% CI: 0.9-1.00) with LUMIPULSE. Double thresholds enabled classification based on predefined sensitivity and specificity, and can be used by clinicians to quickly assess a subject’s likelihood of positivity based on their biomarker levels. Discussion CSF biomarker ratios such as Aβ42/pTau provide high predictive accuracy for brain amyloid and tau deposition. Implementing double thresholds enhances clinical utility by highlighting ambiguous cases requiring further assessment.

Authors

Institutions

Publication Details

Journal
Alzheimer s Research & Therapy
Published
2026-08-14
DOI
https://doi.org/10.1186/s13195-026-02151-z
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal amyloid and tau CSF biomarkers for the detection of amyloid and tau PET positivity in a memory clinic population

Cecilia Boccalini, Valentina Garibotto, Aurélien Lathuilière, Daniele Altomare et al.
Alzheimer s Research & Therapy
Dementia and Cognitive Impairment Research
article

Optimal amyloid and tau CSF biomarkers for the detection of amyloid and tau PET positivity in a memory clinic population

Cecilia Boccalini, Valentina Garibotto, Aurélien Lathuilière, Daniele Altomare, Miguel A. Frias, Federica Ribaldi, Sophie Mutel, Moira Marizzoni, Ilse Kern, Claire Chevalier, Chen Wang, Augusto J. Mendes, Giovanni B. Frisoni, Debora Peretti
article en

Abstract

Abstract Background Accurate detection of Alzheimer’s disease (AD) pathophysiological changes is crucial for research and clinical practice. While positron emission tomography (PET) imaging is an established reference standard for detecting brain amyloid and tau deposition, cerebrospinal fluid (CSF) biomarkers offer a more accessible alternative. This study aimed to identify optimal CSF biomarkers and thresholds for predicting tau and amyloid PET positivity in a memory clinic population. Methods This cross-sectional, observational study included 220 participants from a memory clinic who underwent amyloid or tau PET scans and CSF biomarker analysis using either Fujirebio INNOTEST or LUMIPULSE assays. CSF biomarker performance was assessed via receiver operating characteristic (ROC) analysis. Double-threshold approaches were implemented to address classification uncertainty. Results Ratios combining biomarkers of both amyloid and tau, such as Aβ42/pTau, consistently outperformed individual biomarkers in detecting amyloid and tau PET positivity. For amyloid PET, the Aβ42/pTau ratio achieved an AUC of 0.93 (95% CI: 0.86–0.99) with INNOTEST and an AUC of 0.89 (95% CI: 0.8–0.98) with LUMIPULSE. For tau PET, the Aβ42/pTau ratio achieved an AUC of 0.85 (95% CI: 0.77–0.93) with INNOTEST and an AUC of 0.97 (95% CI: 0.9-1.00) with LUMIPULSE. Double thresholds enabled classification based on predefined sensitivity and specificity, and can be used by clinicians to quickly assess a subject’s likelihood of positivity based on their biomarker levels. Discussion CSF biomarker ratios such as Aβ42/pTau provide high predictive accuracy for brain amyloid and tau deposition. Implementing double thresholds enhances clinical utility by highlighting ambiguous cases requiring further assessment.

Alzheimer s Research & Therapy
University of Geneva (CH), University of Applied Sciences and Arts of Southern Switzerland (CH), University Hospital of Geneva (CH), Centro San Giovanni di Dio Fatebenefratelli (IT), Centre d'Imagerie BioMedicale (CH), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Geneva College (US)
Université de Genève
Good health and well-being
Openalex Percentile: Top 9%
Dementia and Cognitive Impairment Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.