Preventing Participant Leakage in Reissued Clinical AI Benchmarks: A Biomedical Informatics Evaluation Protocol and DAIC-WOZ/E-DAIC Audit

BACKGROUND: Biomedical informatics increasingly reuses clinical artificial intelligence (AI) benchmarks, yet successor releases are often treated as independent external corpora. If the same participants reappear under new corpus names, features, or partition files, evaluation can become internal while reported as external. OBJECTIVES: To define successor-release participant leakage as a benchmark-integrity threat, operationalize a pre-evaluation audit and leak-free protocol, and demonstrate its impact using the Distress Analysis Interview Corpus, Wizard-of-Oz condition (DAIC-WOZ), and the Extended DAIC (E-DAIC) depression-screening benchmarks. METHODS: We audited release lineage and participant identity using persistent identifiers, content hashing, Patient Health Questionnaire-8 (PHQ-8) label reconciliation, and fold-transition cross-tabulation. We compared leaky and participant-disjoint E-DAIC-to-DAIC-WOZ protocols on the same held-out participants using paired bootstrap inference, and derived conservative leak-free reference baselines across standard pipelines. RESULTS: All 189 DAIC-WOZ participants reappeared in E-DAIC with byte-identical recordings and identical PHQ-8 totals. Across official partitions, 104 of 189 changed fold. Training on E-DAIC and evaluating on the DAIC-WOZ test set placed 47/47 test participants in the model-development pool; the reverse direction was clean. The leaky acoustic protocol yielded area under the receiver operating characteristic curve (AUROC) 0.797 versus 0.569 after deduplication, with paired Delta AUROC +0.227 (95% confidence interval +0.106 to +0.372; two-sided p < 0.001). At matched training size, Delta AUROC was +0.249. A generic visual classifier reached AUROC 0.887 on a blended external set but 0.562 on the unseen AI-only portion. Leak-free reference baselines were approximately AUROC 0.60. CONCLUSIONS: Successor-release participant leakage is a preventable evaluation failure in clinical AI benchmark reuse. Before pooling, external validation, or model comparison, biomedical informatics studies should document release lineage, verify participant identity at the signal or record level, reconcile labels, deduplicate across releases, and enforce participant-disjoint evaluation.

Authors

Institutions

Publication Details

Journal
Methods of Information in Medicine
Published
2026-08-14
DOI
https://doi.org/10.1055/a-2938-1280
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preventing Participant Leakage in Reissued Clinical AI Benchmarks: A Biomedical Informatics Evaluation Protocol and DAIC-WOZ/E-DAIC Audit

Minoru Hattori, Naoko Hasunuma
Methods of Information in Medicine
Artificial Intelligence in Healthcare and Education
article

Preventing Participant Leakage in Reissued Clinical AI Benchmarks: A Biomedical Informatics Evaluation Protocol and DAIC-WOZ/E-DAIC Audit

Minoru Hattori, Naoko Hasunuma
article en

Abstract

BACKGROUND: Biomedical informatics increasingly reuses clinical artificial intelligence (AI) benchmarks, yet successor releases are often treated as independent external corpora. If the same participants reappear under new corpus names, features, or partition files, evaluation can become internal while reported as external. OBJECTIVES: To define successor-release participant leakage as a benchmark-integrity threat, operationalize a pre-evaluation audit and leak-free protocol, and demonstrate its impact using the Distress Analysis Interview Corpus, Wizard-of-Oz condition (DAIC-WOZ), and the Extended DAIC (E-DAIC) depression-screening benchmarks. METHODS: We audited release lineage and participant identity using persistent identifiers, content hashing, Patient Health Questionnaire-8 (PHQ-8) label reconciliation, and fold-transition cross-tabulation. We compared leaky and participant-disjoint E-DAIC-to-DAIC-WOZ protocols on the same held-out participants using paired bootstrap inference, and derived conservative leak-free reference baselines across standard pipelines. RESULTS: All 189 DAIC-WOZ participants reappeared in E-DAIC with byte-identical recordings and identical PHQ-8 totals. Across official partitions, 104 of 189 changed fold. Training on E-DAIC and evaluating on the DAIC-WOZ test set placed 47/47 test participants in the model-development pool; the reverse direction was clean. The leaky acoustic protocol yielded area under the receiver operating characteristic curve (AUROC) 0.797 versus 0.569 after deduplication, with paired Delta AUROC +0.227 (95% confidence interval +0.106 to +0.372; two-sided p < 0.001). At matched training size, Delta AUROC was +0.249. A generic visual classifier reached AUROC 0.887 on a blended external set but 0.562 on the unseen AI-only portion. Leak-free reference baselines were approximately AUROC 0.60. CONCLUSIONS: Successor-release participant leakage is a preventable evaluation failure in clinical AI benchmark reuse. Before pooling, external validation, or model comparison, biomedical informatics studies should document release lineage, verify participant identity at the signal or record level, reconcile labels, deduplicate across releases, and enforce participant-disjoint evaluation.

Methods of Information in Medicine
Hiroshima University of Economics (JP)
Openalex Percentile: Top 13%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.