COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY

Objective: This study aimed to compare patient radiation exposure between biplane and monoplane digital subtraction angiography (DSA) systems during diagnostic cerebral angiography and evaluate the dose efficiency of modern dual-plane technology.Materials and Methods: This retrospective single-center study included 61 consecutive patients who underwent diagnostic cerebral DSA between November 2021 and April 2022. Examinations were performed using a monoplane system (n=31) and a biplane system equipped with advanced dose reduction technology (n=30). For each procedure, total fluoroscopy time, fluoroscopy dose-area product (DAP), exposure DAP, total DAP, and cumulative air kerma were recorded. Groups were compared using independent-samples t-tests or Mann–Whitney U tests, with p<0.05 considered statistically significant.Results: Fluoroscopy time was comparable between the monoplane and biplane groups (p=0.736). The biplane system produced a significantly greater number of image acquisitions (p<0.001) yet achieved markedly lower radiation doses. Median exposure DAP and total DAP were reduced by approximately 25–35%, and total air kerma was significantly lower in the biplane group (p<0.001). Fluoroscopy DAP was slightly higher for the biplane system (p=0.008), likely reflecting occasional dual-plane use during complex catheter navigation.Conclusion: Despite acquiring more projections, the biplane DSA system demonstrated substantially lower total radiation exposure than the monoplane system. These results indicate that modern biplane technology with advanced dose reduction algorithms (ClarityIQ) offers improved dose efficiency and enhanced patient safety in diagnostic cerebral angiography. The observed reduction in radiation dose may reflect not only the biplane configuration itself but also differences in system generation, image-processing algorithms, and acquisition protocols.

Authors

Institutions

Publication Details

Journal
Journal of Istanbul Faculty of Medicine / İstanbul Tıp Fakültesi Dergisi
Published
2026-08-14
DOI
https://doi.org/10.26650/iuitfd.1828054
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY

Mehmet Barbüroğlu, Berke Ersoy, Mücahit Karabulut, Hakan Ayyıldız
Journal of Istanbul Faculty of Medicine / İstanbul Tıp Fakültesi Dergisi
Radiation Dose and Imaging
article

COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY

Mehmet Barbüroğlu, Berke Ersoy, Mücahit Karabulut, Hakan Ayyıldız
article en

Abstract

Objective: This study aimed to compare patient radiation exposure between biplane and monoplane digital subtraction angiography (DSA) systems during diagnostic cerebral angiography and evaluate the dose efficiency of modern dual-plane technology.Materials and Methods: This retrospective single-center study included 61 consecutive patients who underwent diagnostic cerebral DSA between November 2021 and April 2022. Examinations were performed using a monoplane system (n=31) and a biplane system equipped with advanced dose reduction technology (n=30). For each procedure, total fluoroscopy time, fluoroscopy dose-area product (DAP), exposure DAP, total DAP, and cumulative air kerma were recorded. Groups were compared using independent-samples t-tests or Mann–Whitney U tests, with p<0.05 considered statistically significant.Results: Fluoroscopy time was comparable between the monoplane and biplane groups (p=0.736). The biplane system produced a significantly greater number of image acquisitions (p<0.001) yet achieved markedly lower radiation doses. Median exposure DAP and total DAP were reduced by approximately 25–35%, and total air kerma was significantly lower in the biplane group (p<0.001). Fluoroscopy DAP was slightly higher for the biplane system (p=0.008), likely reflecting occasional dual-plane use during complex catheter navigation.Conclusion: Despite acquiring more projections, the biplane DSA system demonstrated substantially lower total radiation exposure than the monoplane system. These results indicate that modern biplane technology with advanced dose reduction algorithms (ClarityIQ) offers improved dose efficiency and enhanced patient safety in diagnostic cerebral angiography. The observed reduction in radiation dose may reflect not only the biplane configuration itself but also differences in system generation, image-processing algorithms, and acquisition protocols.

Journal of Istanbul Faculty of Medicine / İstanbul Tıp Fakültesi DergisiVol. 89(3)
Yozgat Bozok Üniversitesi (TR), İstanbul Başakşehir Çam ve Sakura Şehir Hastanesi, Istanbul University (TR)
Openalex Percentile: Top 10%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.