Finding and Understanding the Limiting Oxygen Concentration for Oxygen Reduction Systems

Abstract Automated storage systems and large-scale freezers can be challenging for conventional fire protection systems. Instead, an oxygen reduction system (ORS) could be a suitable option. In an ORS the design oxygen concentration is the key parameter for the level of protection achieved by the system. However, current methods for determining this concentration yield varying results and either require large and complex test setups or arrive at overly optimistic levels for protection. In this paper, an experimental method for using the controlled atmosphere cone calorimeter (CACC) to find the limiting oxygen concentration at extinction (LOC ext ) is proposed. The results from the CACC showed good agreement with limiting oxygen concentrations (LOC) determined by large-scale; indicating that the CACC could serve as a cost-effective alternative for determining the LOC of ordinary combustibles for ORS applications. Furthermore, thermal analysis and experiments using both nitrogen and carbon dioxide highlights that the thermal properties of the diluent gas, rather than oxygen displacement and chemical quenching, are the primary factors influencing the LOC. Hence, the findings in this paper increase the understanding of ORS systems and offer a way to determine the LOC for ORS based on small-scale testing.

Authors

Institutions

Publication Details

Journal
Fire Technology
Published
2026-08-14
DOI
https://doi.org/10.1007/s10694-026-01979-z
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finding and Understanding the Limiting Oxygen Concentration for Oxygen Reduction Systems

Joakim Åström, Patrick Van Hees, Martin Nilsson
Fire Technology
Fire dynamics and safety research
article

Finding and Understanding the Limiting Oxygen Concentration for Oxygen Reduction Systems

Joakim Åström, Patrick Van Hees, Martin Nilsson
article en

Abstract

Abstract Automated storage systems and large-scale freezers can be challenging for conventional fire protection systems. Instead, an oxygen reduction system (ORS) could be a suitable option. In an ORS the design oxygen concentration is the key parameter for the level of protection achieved by the system. However, current methods for determining this concentration yield varying results and either require large and complex test setups or arrive at overly optimistic levels for protection. In this paper, an experimental method for using the controlled atmosphere cone calorimeter (CACC) to find the limiting oxygen concentration at extinction (LOC ext ) is proposed. The results from the CACC showed good agreement with limiting oxygen concentrations (LOC) determined by large-scale; indicating that the CACC could serve as a cost-effective alternative for determining the LOC of ordinary combustibles for ORS applications. Furthermore, thermal analysis and experiments using both nitrogen and carbon dioxide highlights that the thermal properties of the diluent gas, rather than oxygen displacement and chemical quenching, are the primary factors influencing the LOC. Hence, the findings in this paper increase the understanding of ORS systems and offer a way to determine the LOC for ORS based on small-scale testing.

Fire TechnologyVol. 62(6)
Lund University (SE), Zurich Insurance Group (Switzerland) (CH), Fire Safety Design (SE)
Lunds Universitet
Openalex Percentile: Top 10%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Finding and Understanding the Limiting Oxygen Concentration for Oxygen Reduction Systems — Joakim Åström, Patrick Van Hees, et al. · Fire Technology (2026) | TGRS Research Map | TGRS