Broadband VFTO Measurement Method Based on Modified UHF Sensors

The very fast transient overvoltage (VFTO) generated by the operation of disconnectors in gas-insulated switchgears (GIS) features a wide frequency band and a steep rising edge, posing a severe threat to the safe and stable operation of power grids. Accurate measurement of VFTO is a core prerequisite for the insulation protection design of power equipment. Aimed at solving the problem that ultra-high frequency (UHF) sensors widely installed in existing GIS are limited by—the built-in inductance and inability to fully reconstruct the VFTO waveform—this paper proposes a broadband VFTO measurement method based on modified UHF sensors. The VFTO measuring system based on UHF sensors was constructed and tested by modifying the structure of UHF sensors and a broadband pulse source capable of outputting equivalent frequencies from 1 kHz to 10 MHz. The results showed that the measuring system exhibited excellent high-frequency (100 kHz~1 MHz) response performance but poor low-frequency (~1 kHz) response. By introducing a voltage-follower impedance transformation module based on a high-speed operational amplifier, the UHF measuring system could accurately reconstruct the VFTO waveform during the opening and closing of the 750 kV GIS disconnector. This non-contact measurement scheme provided a highly promising and reliable technical path for on-site VFTO detection for in-service equipment without altering the existing structure of GIS.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-08-14
DOI
https://doi.org/10.3390/en19163819
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broadband VFTO Measurement Method Based on Modified UHF Sensors

Xiaoang Li, Ling Xiang, Dingge Yang, Ruotian Wang et al.
Energies
High voltage insulation and dielectric phenomena
article

Broadband VFTO Measurement Method Based on Modified UHF Sensors

Xiaoang Li, Ling Xiang, Dingge Yang, Ruotian Wang, Yin Liu, Can Guo
article en

Abstract

The very fast transient overvoltage (VFTO) generated by the operation of disconnectors in gas-insulated switchgears (GIS) features a wide frequency band and a steep rising edge, posing a severe threat to the safe and stable operation of power grids. Accurate measurement of VFTO is a core prerequisite for the insulation protection design of power equipment. Aimed at solving the problem that ultra-high frequency (UHF) sensors widely installed in existing GIS are limited by—the built-in inductance and inability to fully reconstruct the VFTO waveform—this paper proposes a broadband VFTO measurement method based on modified UHF sensors. The VFTO measuring system based on UHF sensors was constructed and tested by modifying the structure of UHF sensors and a broadband pulse source capable of outputting equivalent frequencies from 1 kHz to 10 MHz. The results showed that the measuring system exhibited excellent high-frequency (100 kHz~1 MHz) response performance but poor low-frequency (~1 kHz) response. By introducing a voltage-follower impedance transformation module based on a high-speed operational amplifier, the UHF measuring system could accurately reconstruct the VFTO waveform during the opening and closing of the 750 kV GIS disconnector. This non-contact measurement scheme provided a highly promising and reliable technical path for on-site VFTO detection for in-service equipment without altering the existing structure of GIS.

EnergiesVol. 19(16)
Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 22%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.