Fractal Acoustic Emission Characteristics and Energy Evolution of High-Water-Resistance Concrete Backfill: Roles of Water-to-Cement Ratio and Fiber Volume Fraction

Fiber-reinforced high-water-resistance concrete backfill (FHWCB) is a rapid-setting cementitious backfill system used for underground support and backfilling, but its stability is strongly affected by mixture water content and fiber dispersion. This study investigated the fresh-state behavior, mechanical performance, acoustic emission (AE) fractal characteristics, b-value response, and energy evolution of FHWCB. Mixtures with water-to-cement ratios (w/c) of 1.0–1.8 and fiber volume fractions (Vf) of 0–0.5% were prepared and tested using fresh property measurements, unconfined compression, thermogravimetry, AE monitoring, correlation dimension analysis, b-value analysis, and strain energy partitioning. Increasing w/c improved flowability and delayed setting, but weakened the hydration skeleton and reduced early-age compressive strength by approximately 56–61%. Fiber reinforcement showed a non-monotonic effect: Vf = 0.3% increased compressive strength by approximately 16–26%, whereas excessive fiber addition reduced strength because of fiber clustering and weak local zones. AE amplitude sequences exhibited measurable fractal characteristics. A higher correlation dimension indicated distributed microdamage, while decreasing correlation dimension and b-value reflected the transition toward localized macrocrack growth. Energy analysis showed that the peak elastic strain energy density decreased from approximately 0.60 to 0.39 MJ/m3 as w/c increased. The proposed AE fractal–b-value–energy framework provides a quantitative basis for tracking damage progression and optimizing FHWCB for underground engineering.

Authors

Institutions

Publication Details

Journal
Fractal and Fractional
Published
2026-08-14
DOI
https://doi.org/10.3390/fractalfract10080555
Primary Topic
Tailings Management and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fractal Acoustic Emission Characteristics and Energy Evolution of High-Water-Resistance Concrete Backfill: Roles of Water-to-Cement Ratio and Fiber Volume Fraction

Zizheng Zhang, Jianxiong Yang, Zilu Liu, Shuaigang Liu et al.
Fractal and Fractional
Tailings Management and Properties
article

Fractal Acoustic Emission Characteristics and Energy Evolution of High-Water-Resistance Concrete Backfill: Roles of Water-to-Cement Ratio and Fiber Volume Fraction

Zizheng Zhang, Jianxiong Yang, Zilu Liu, Shuaigang Liu, Kun Fang, Xiaohe Wang
article en

Abstract

Fiber-reinforced high-water-resistance concrete backfill (FHWCB) is a rapid-setting cementitious backfill system used for underground support and backfilling, but its stability is strongly affected by mixture water content and fiber dispersion. This study investigated the fresh-state behavior, mechanical performance, acoustic emission (AE) fractal characteristics, b-value response, and energy evolution of FHWCB. Mixtures with water-to-cement ratios (w/c) of 1.0–1.8 and fiber volume fractions (Vf) of 0–0.5% were prepared and tested using fresh property measurements, unconfined compression, thermogravimetry, AE monitoring, correlation dimension analysis, b-value analysis, and strain energy partitioning. Increasing w/c improved flowability and delayed setting, but weakened the hydration skeleton and reduced early-age compressive strength by approximately 56–61%. Fiber reinforcement showed a non-monotonic effect: Vf = 0.3% increased compressive strength by approximately 16–26%, whereas excessive fiber addition reduced strength because of fiber clustering and weak local zones. AE amplitude sequences exhibited measurable fractal characteristics. A higher correlation dimension indicated distributed microdamage, while decreasing correlation dimension and b-value reflected the transition toward localized macrocrack growth. Energy analysis showed that the peak elastic strain energy density decreased from approximately 0.60 to 0.39 MJ/m3 as w/c increased. The proposed AE fractal–b-value–energy framework provides a quantitative basis for tracking damage progression and optimizing FHWCB for underground engineering.

Fractal and FractionalVol. 10(8)
Hunan University of Science and Technology (CN), Sichuan University (CN), China University of Mining and Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 15%
Tailings Management and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.