Dual-wavelength filtering for the detection of blood-spotted eggs

This study developed an image-based dual-wavelength filter method for detecting blood-spotted white-shelled eggs based on transmission spectral analysis. The spectral results identified a pronounced absorption feature near 580 nm in blood-spotted eggs. Accordingly, 580 nm was selected as the blood-sensitive wavelength and 630 nm as the reference wavelength, and the dual-wavelength image intensity ratio was used for detection. Binary logistic regression models were constructed for both the image-based dual-wavelength filter method and the transmission spectroscopy method. The models were evaluated using artificially prepared blood-spotted white-shelled egg samples containing 0.025 and 0.05 mL of blood, together with commercially sourced blood-spotted white-shelled eggs. The retrained image-based dual-wavelength method achieved 84.9% overall accuracy and 83.8% sensitivity for the commercially sourced samples. These results indicate that the proposed method has potential for nondestructive screening of blood-spotted white-shelled eggs under static laboratory conditions.

Authors

Institutions

Publication Details

Journal
Journal of Food Measurement & Characterization
Published
2026-08-14
DOI
https://doi.org/10.1007/s11694-026-04824-7
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-wavelength filtering for the detection of blood-spotted eggs

Chien‐Chung Jeng, Cheng-Han Li, Ming‐Kun Hsieh, Chi-Yu Chen
Journal of Food Measurement & Characterization
Digital Imaging for Blood Diseases
article

Dual-wavelength filtering for the detection of blood-spotted eggs

Chien‐Chung Jeng, Cheng-Han Li, Ming‐Kun Hsieh, Chi-Yu Chen
article en

Abstract

This study developed an image-based dual-wavelength filter method for detecting blood-spotted white-shelled eggs based on transmission spectral analysis. The spectral results identified a pronounced absorption feature near 580 nm in blood-spotted eggs. Accordingly, 580 nm was selected as the blood-sensitive wavelength and 630 nm as the reference wavelength, and the dual-wavelength image intensity ratio was used for detection. Binary logistic regression models were constructed for both the image-based dual-wavelength filter method and the transmission spectroscopy method. The models were evaluated using artificially prepared blood-spotted white-shelled egg samples containing 0.025 and 0.05 mL of blood, together with commercially sourced blood-spotted white-shelled eggs. The retrained image-based dual-wavelength method achieved 84.9% overall accuracy and 83.8% sensitivity for the commercially sourced samples. These results indicate that the proposed method has potential for nondestructive screening of blood-spotted white-shelled eggs under static laboratory conditions.

Journal of Food Measurement & Characterization
National Taichung University of Science and Technology (TW), National Chung Hsing University (TW)
National Chung-Hsing University
Openalex Percentile: Top 11%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.