Association between ASCVD risk score and STOP-BANG questionnaire for obstructive sleep apnea screening: a cross-sectional analysis

Patients may be less likely to be screened by their PCP for OSA compared to CVD. The ASCVD risk score and STOP-BANG questionnaire assess overlapping cardiometabolic risk factors. This study examined the correlation between ASCVD and STOP-BANG scores and whether combining them alters OSA screening performance compared to STOP-BANG alone. A cross-sectional secondary analysis of 201 participants (ages 40–75) from two National Sleep Research Resource datasets were utilized. Spearman correlations were calculated between ASCVD, STOP-BANG, and apnea–hypopnea index (AHI). Diagnostic performance metrics (sensitivity, specificity, positive and negative predictive values, likelihood ratios, area under the curve) were calculated for ASCVD (≥ 7.5%), STOP-BANG (≥ 3), and their combination for detecting at least mild OSA (AHI > 5). Univariable and multivariable logistic regression analyses assessed independent associations. ASCVD and STOP-BANG demonstrated strong correlation (r = 0.79, 95% CI 0.76–0.81). STOP-BANG showed superior sensitivity (0.91 vs. 0.52) compared to ASCVD. Combining ASCVD with STOP-BANG modestly improved specificity (0.66) and likelihood ratio (2.57) versus STOP-BANG alone. STOP-BANG, ASCVD, and the combined model demonstrated AUCs of 0.67, 0.64, and 0.77, respectively, with overlapping confidence intervals, indicating modest and not clearly different discrimination between models. In multivariable regression, only STOP-BANG remained significantly associated with OSA (OR 1.60 per point, 95% CI 1.30–1.97). ASCVD and STOP-BANG scores are strongly correlated, reflecting shared cardiometabolic risk factors. STOP-BANG remains the superior screening tool for OSA, whereas ASCVD appears to reflect overlapping risk burden without providing additional discriminatory value for OSA screening.

Authors

Institutions

Publication Details

Journal
Sleep Science and Practice
Published
2026-08-14
DOI
https://doi.org/10.1186/s41606-026-00197-4
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association between ASCVD risk score and STOP-BANG questionnaire for obstructive sleep apnea screening: a cross-sectional analysis

Ananda Sen, Max Goodman, Mehwish Sajid
Sleep Science and Practice
Obstructive Sleep Apnea Research
article

Association between ASCVD risk score and STOP-BANG questionnaire for obstructive sleep apnea screening: a cross-sectional analysis

Ananda Sen, Max Goodman, Mehwish Sajid
article en

Abstract

Patients may be less likely to be screened by their PCP for OSA compared to CVD. The ASCVD risk score and STOP-BANG questionnaire assess overlapping cardiometabolic risk factors. This study examined the correlation between ASCVD and STOP-BANG scores and whether combining them alters OSA screening performance compared to STOP-BANG alone. A cross-sectional secondary analysis of 201 participants (ages 40–75) from two National Sleep Research Resource datasets were utilized. Spearman correlations were calculated between ASCVD, STOP-BANG, and apnea–hypopnea index (AHI). Diagnostic performance metrics (sensitivity, specificity, positive and negative predictive values, likelihood ratios, area under the curve) were calculated for ASCVD (≥ 7.5%), STOP-BANG (≥ 3), and their combination for detecting at least mild OSA (AHI > 5). Univariable and multivariable logistic regression analyses assessed independent associations. ASCVD and STOP-BANG demonstrated strong correlation (r = 0.79, 95% CI 0.76–0.81). STOP-BANG showed superior sensitivity (0.91 vs. 0.52) compared to ASCVD. Combining ASCVD with STOP-BANG modestly improved specificity (0.66) and likelihood ratio (2.57) versus STOP-BANG alone. STOP-BANG, ASCVD, and the combined model demonstrated AUCs of 0.67, 0.64, and 0.77, respectively, with overlapping confidence intervals, indicating modest and not clearly different discrimination between models. In multivariable regression, only STOP-BANG remained significantly associated with OSA (OR 1.60 per point, 95% CI 1.30–1.97). ASCVD and STOP-BANG scores are strongly correlated, reflecting shared cardiometabolic risk factors. STOP-BANG remains the superior screening tool for OSA, whereas ASCVD appears to reflect overlapping risk burden without providing additional discriminatory value for OSA screening.

Sleep Science and PracticeVol. 10(1)
University of Michigan (US)
National Institutes of Health, National Heart, Lung, and Blood Institute, National Center for Research Resources
Openalex Percentile: Top 10%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.