276 Days of Support by a Micro‐Axial Left Ventricular Assist Device as a Bridge to Heart Transplant

The Impella 5.5 is a surgically implanted micro-axial left ventricular assist device (LVAD) increasingly utilized for mechanical circulatory support (MCS) in cardiogenic shock. While typically used for acute support up to FDA-approved 14 days, reports of prolonged utilization remain limited. We present the case of a 69-year-old male who presented with severe biventricular failure and cardiogenic shock who was bridged to heart transplantation (HT) utilizing a single Impella 5.5 for a total of 276 days. His prolonged support course was managed through a multidisciplinary approach addressing recurrent ventricular arrhythmias, renal failure, heparin-induced thrombocytopenia, and device management (suction alarms and purge flow limitations). Following successful HT, the explanted device demonstrated no mechanical injury or thrombus, and pathologic examination revealed no significant device-related structural heart damage. The patient was discharged without major complications and continued to do well at 5-month follow-up.

Authors

Institutions

Publication Details

Journal
Artificial Organs
Published
2026-08-13
DOI
https://doi.org/10.1111/aor.70225
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

276 Days of Support by a Micro‐Axial Left Ventricular Assist Device as a Bridge to Heart Transplant

Gregg M. Lanier, Junichi Shimamura, Stephen Pan, David Spielvogel et al.
Artificial Organs
Mechanical Circulatory Support Devices
article

276 Days of Support by a Micro‐Axial Left Ventricular Assist Device as a Bridge to Heart Transplant

Gregg M. Lanier, Junichi Shimamura, Stephen Pan, David Spielvogel, Chhaya Aggarwal, Alan Gass, Avi Levine
article en

Abstract

The Impella 5.5 is a surgically implanted micro-axial left ventricular assist device (LVAD) increasingly utilized for mechanical circulatory support (MCS) in cardiogenic shock. While typically used for acute support up to FDA-approved 14 days, reports of prolonged utilization remain limited. We present the case of a 69-year-old male who presented with severe biventricular failure and cardiogenic shock who was bridged to heart transplantation (HT) utilizing a single Impella 5.5 for a total of 276 days. His prolonged support course was managed through a multidisciplinary approach addressing recurrent ventricular arrhythmias, renal failure, heparin-induced thrombocytopenia, and device management (suction alarms and purge flow limitations). Following successful HT, the explanted device demonstrated no mechanical injury or thrombus, and pathologic examination revealed no significant device-related structural heart damage. The patient was discharged without major complications and continued to do well at 5-month follow-up.

Artificial Organs
Westchester Medical Center (US), New York Medical College (US)
Good health and well-being
Openalex Percentile: Top 18%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

276 Days of Support by a Micro‐Axial Left Ventricular Assist Device as a Bridge to Heart Transplant — Gregg M. Lanier, Junichi Shimamura, et al. · Artificial Organs (2026) | TGRS Research Map | TGRS