Synergistic Thermal Hazard Mitigation and Smoke Control by Water Mist and Semi-Transverse Mechanical Ventilation for Battery Electric Vehicle Fires in Road Tunnels

Battery electric vehicle (BEV) fires in road tunnels can intensify thermal, smoke transport, visibility, and CO exposure hazards under confined ventilation. This study evaluated the combined mitigation performance of water mist and semi-transverse mechanical ventilation. A three-dimensional PyroSim/FDS model of a 200 m × 10 m × 5 m tunnel was established with a 7 MW BEV design fire at the midpoint. The prescribed-source model was assessed against a reduced-scale lithium-ion battery tunnel experiment; at the representative monitoring location, the simulated temperature history reproduced the main trend, with deviations of approximately 7% and 10% at the first and second peaks. Thirty-six coupled cases examined ventilation mode, nominal opening velocity, nozzle arrangement and spacing, flow rate input, droplet diameter, and spray cone angle. Supply ventilation improved hot-smoke-layer cooling and visibility, whereas exhaust ventilation more effectively reduced the local CO volume fraction. Under the baseline weighting scheme, the highest-ranked case reduced the peak local ceiling-region and near-fire gas temperatures by 77.8% and 82.2%, increased average visibility during 200–500 s by 42.9%, and achieved a comprehensive relative mitigation index (CRMI) of 56.6%. Two supplementary nominal 10 MW simulations showed that this case retained substantial thermal control, reducing the two peak temperatures by 65.7% and 74.1%, but did not improve local visibility or CO. Thus, the thermal-mitigation trend persisted at the higher nominal input, whereas the full multi-hazard ranking was not transferable across fire sizes.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-08-14
DOI
https://doi.org/10.3390/fire9080351
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergistic Thermal Hazard Mitigation and Smoke Control by Water Mist and Semi-Transverse Mechanical Ventilation for Battery Electric Vehicle Fires in Road Tunnels

Yang Cao, Shuangjie Mei, Xuefeng Han
Fire
Fire dynamics and safety research
article

Synergistic Thermal Hazard Mitigation and Smoke Control by Water Mist and Semi-Transverse Mechanical Ventilation for Battery Electric Vehicle Fires in Road Tunnels

Yang Cao, Shuangjie Mei, Xuefeng Han
article en

Abstract

Battery electric vehicle (BEV) fires in road tunnels can intensify thermal, smoke transport, visibility, and CO exposure hazards under confined ventilation. This study evaluated the combined mitigation performance of water mist and semi-transverse mechanical ventilation. A three-dimensional PyroSim/FDS model of a 200 m × 10 m × 5 m tunnel was established with a 7 MW BEV design fire at the midpoint. The prescribed-source model was assessed against a reduced-scale lithium-ion battery tunnel experiment; at the representative monitoring location, the simulated temperature history reproduced the main trend, with deviations of approximately 7% and 10% at the first and second peaks. Thirty-six coupled cases examined ventilation mode, nominal opening velocity, nozzle arrangement and spacing, flow rate input, droplet diameter, and spray cone angle. Supply ventilation improved hot-smoke-layer cooling and visibility, whereas exhaust ventilation more effectively reduced the local CO volume fraction. Under the baseline weighting scheme, the highest-ranked case reduced the peak local ceiling-region and near-fire gas temperatures by 77.8% and 82.2%, increased average visibility during 200–500 s by 42.9%, and achieved a comprehensive relative mitigation index (CRMI) of 56.6%. Two supplementary nominal 10 MW simulations showed that this case retained substantial thermal control, reducing the two peak temperatures by 65.7% and 74.1%, but did not improve local visibility or CO. Thus, the thermal-mitigation trend persisted at the higher nominal input, whereas the full multi-hazard ranking was not transferable across fire sizes.

FireVol. 9(8)
Nanjing Tech University (CN)
Openalex Percentile: Top 10%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synergistic Thermal Hazard Mitigation and Smoke Control by Water Mist and Semi-Transverse Mechanical Ventilation for Battery Electric Vehicle Fires in Road Tunnels — Yang Cao, Shuangjie Mei, et al. · Fire (2026) | TGRS Research Map | TGRS