Gas-driven needle-free dental injection enables tunable and predictable soft-tissue penetration: high-speed kinematic and micro-computed tomography validation

Needle-free jet injectors are a promising alternative to conventional dental needles, particularly for patients with injection-related fear. However, the actuation mechanism can substantially affect jet formation, delivery consistency, and tissue penetration. This study compared portable gas-driven jet injectors with a conventional spring-driven device and evaluated whether jet velocity could be used to modulate penetration behavior in soft tissue. Four gas-driven injectors with different inlet-side restriction settings were compared with a spring-driven comparator. High-speed imaging was used to quantify piston motion, flow rate, and jet velocity. Soft-tissue penetration was assessed in ex vivo chicken breast using a radiopaque silver nitrate tracer and micro-computed tomography (micro-CT). Penetration volume, maximum depth, maximum cross-sectional area, depth of maximum area, and average cross-sectional area were analyzed. The gas-driven injectors showed smooth piston advancement, quasi-steady jet profiles, and complete discharge, whereas the spring-driven comparator showed an impulsive early peak, recoil, fan-spray tendency, and incomplete discharge. Mean jet velocity exceeded 13 m/s in all gas-driven groups but was 2.40 m/s in the spring-driven group despite a much higher peak velocity. Micro-CT showed no significant between-group difference in detectable tracer volume. Increasing jet velocity in the gas-driven groups was associated with deeper and narrower penetration tracts, whereas lower jet velocities produced shallower and broader dispersion. Gas-driven needle-free injection provided more stable kinematics and more controllable penetration geometry than the spring-driven comparator under the present ex vivo conditions. Velocity-based regulation may enable procedure- and site-specific optimization of needle-free dental local anesthesia, although clinical validation in intraoral tissues is still required.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-08-14
DOI
https://doi.org/10.1186/s12903-026-09612-9
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gas-driven needle-free dental injection enables tunable and predictable soft-tissue penetration: high-speed kinematic and micro-computed tomography validation

Teo Jeon Shin, Ji‐Soo Song, Hyuntae Kim, Hong‐Keun Hyun et al.
BMC Oral Health
Endodontics and Root Canal Treatments
article

Gas-driven needle-free dental injection enables tunable and predictable soft-tissue penetration: high-speed kinematic and micro-computed tomography validation

Teo Jeon Shin, Ji‐Soo Song, Hyuntae Kim, Hong‐Keun Hyun, Mohammad Alkeshan, Jeonghyun Yoon, Mohammad AlQarni
article en

Abstract

Needle-free jet injectors are a promising alternative to conventional dental needles, particularly for patients with injection-related fear. However, the actuation mechanism can substantially affect jet formation, delivery consistency, and tissue penetration. This study compared portable gas-driven jet injectors with a conventional spring-driven device and evaluated whether jet velocity could be used to modulate penetration behavior in soft tissue. Four gas-driven injectors with different inlet-side restriction settings were compared with a spring-driven comparator. High-speed imaging was used to quantify piston motion, flow rate, and jet velocity. Soft-tissue penetration was assessed in ex vivo chicken breast using a radiopaque silver nitrate tracer and micro-computed tomography (micro-CT). Penetration volume, maximum depth, maximum cross-sectional area, depth of maximum area, and average cross-sectional area were analyzed. The gas-driven injectors showed smooth piston advancement, quasi-steady jet profiles, and complete discharge, whereas the spring-driven comparator showed an impulsive early peak, recoil, fan-spray tendency, and incomplete discharge. Mean jet velocity exceeded 13 m/s in all gas-driven groups but was 2.40 m/s in the spring-driven group despite a much higher peak velocity. Micro-CT showed no significant between-group difference in detectable tracer volume. Increasing jet velocity in the gas-driven groups was associated with deeper and narrower penetration tracts, whereas lower jet velocities produced shallower and broader dispersion. Gas-driven needle-free injection provided more stable kinematics and more controllable penetration geometry than the spring-driven comparator under the present ex vivo conditions. Velocity-based regulation may enable procedure- and site-specific optimization of needle-free dental local anesthesia, although clinical validation in intraoral tissues is still required.

BMC Oral Health
Seoul National University (KR), Maternity and Children's Hospital (SA), King Abdullah Medical City (SA)
Openalex Percentile: Top 8%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.